Articles by Ronald E. Majors - Chromatography Online
Articles by Ronald E. Majors

Ronald E. Majors

"Column Watch" and "Sample Prep Perspectives" Editor

Ron Majors, editor of "Column Watch" and "Sample Prep Perspectives," has been with LCGC North America for over 26 years. Currently a senior scientist with Agilent Technologies, Wilmington, Delaware, Ron is known industry-wide as one of the premier chromatography experts in the field. He is also a member of LCGC's editorial advisory board.

Articles
The State of the Art in Chiral Capillary Gas Chromatography
May 1, 2012

A review of the historical development and latest trends in phase development in the field of chiral capillary gas chromatography. A range of novel applications in chiral capillary GC are also described.

Developments in HPLC/UHPLC Column Technology
April 1, 2012

A discussion of new column packing materials — including sub-2-?m particles, superficially porous particles, and second-generation monoliths — and their impact on instrumentation and laboratory productivity

Current Trends in HPLC Column Usage
March 1, 2012

The results of a recent survery on stationary phases used in high performance liquid chromatography (HPLC) are revealed.

It's All About Selectivity
February 1, 2012

This article looks at selectivity throughout the whole sample analysis cycle from the sampling stage, through sample preparation, sample introduction, analyte separation, analyte detection, data analysis and report generation.

Current Trends in HPLC Column Usage
January 1, 2012

The results of a recent survey on stationary phases used in high performance liquid chromatography (HPLC) are revealed.

Hollow-Fibre Liquid-Phase Microextraction in the Three-Phase Mode – Practical Considerations
December 1, 2011

Describes practical aspects of hollow-fibre liquid-phase microextraction in the three phase mode (HF3LPME) and also electromembrane extraction (EME).

Highlights of HPLC 2011
November 1, 2011

A review of some of the advances in technology and new applications presented at HPLC 2011, held in Budapest, Hungary.

Highlights of HPLC 2011
September 1, 2011

A presentation of the overall trends in liquid-phase chromatography observed at the symposium, as well as the awards presented and the opening plenary session

Method Translation in Liquid Chromatography
August 1, 2011

An overview of the method translation calculators to make conversions from conventional HPLC to high-throughput HPLC and UHPLC.