In an ideal chromatographic separation, all sample components would be isolated from each other and detected as fully resolved peaks. However, it is not uncommon to encounter some degree of overlap. In extreme cases, what appears to be a single peak contains in fact two or more coeluting components. This article discusses how to check the purity of such peaks in order to correctly interpret the results of the analysis.
Apr 19, 2016
By LCGC Editors
In an ideal chromatographic separation, all sample components would be isolated from each other and detected as fully resolved peaks. However, it is not uncommon to encounter some degree of overlap. In extreme cases, what appears to be a single peak contains in fact two or more coeluting components. This article discusses how to check the purity of such peaks in order to correctly interpret the results of the analysis.
Mar 08, 2016
LCGC Asia Pacific
By LCGC Editors
An excerpt from LCGC’s e-learning tutorial on biochromatography at CHROMacademy.com
Feb 29, 2016
By LCGC Editors
The first question to ask is, why would headspace GC be a good sampling technique?
Feb 09, 2016
By LCGC Editors
If the hold-up volume (time) is the extra-column dead volume expressed in time or volume what is the column dead volume and how can it be calculated?
Nov 10, 2015
By LCGC Editors
They say a picture paints a thousand words…This month I’ve taken inspiration from a recent webcast, presented at www.chromacademy.com, in which I presented real data from our work that represents some ‘classic’ GC problems.
Sep 13, 2015
By LCGC Editors
Static headspace sampling is typically used for the determination of volatile and semi-volatile analytes in liquids and, more rarely, solid matrices. Application examples include the analysis of alcohols in blood, residual solvents in pharmaceuticals, flavours and taints in food and beverages as well as fragrances in perfumes and detergents.
Jul 07, 2015
By LCGC Editors
Understanding how an instrument works is great, but when do you have time to read a textbook, or go to a course? Let CHROMacademy help. Dip in and out of concise modules and take 5 minutes to learn a little about the fundamentals of your analytical technique. Why not delve into GC-MS ionisation techniques right now?
May 19, 2015
By LCGC Editors
Change is always a scary concept but let us dispel some of the fear associated with changing your helium carrier gas to hydrogen by answering some of the most common questions posed to us.
Apr 22, 2015
By LCGC Editors
The following article from LCGC's ChromAcademy introduces the fundamentals of biopharmaceutical analysis and cover the use of reversed-phase HPLC in the analysis of biomolecules.