The LCGC Blog

Sep 10, 2014
E-Separation Solutions
By LCGC Editors
Gas Chromatography with Vacuum Ultraviolet Absorption Detection
Aug 21, 2014
E-Separation Solutions
By LCGC Editors
Tony Taylor discusses the importance of keeping extra column volume as small as possible, especially when using UHPLC equipment.
Aug 13, 2014
E-Separation Solutions
By LCGC Editors
When you begin to now combine advances in superficially porous media to achieve high efficiency with novel and predictable new stationary phases to achieve high selectivity, then it sounds like the evolution of HPLC and UHPLC phases over the past decade or more has brought some exciting new possibilities.
Jul 17, 2014
LCGC North America
By LCGC Editors
Much has been written about column overload, however, I've seen many instances lately in which overload may not be instantly recognized, or causes problems that may not normally be attributed to overload. Therefore, I wanted to explain how to spot and deal with different types of overload situations.
Jul 10, 2014
E-Separation Solutions
By LCGC Editors
If you ask scientists, it does not take long before you realize that there is quite a bit of variety in the different search engines that they prefer.
Jun 19, 2014
E-Separation Solutions
By LCGC Editors
The International Symposium on Capillary Chromatography (ISCC) and GCxGC Symposium combined conference provides an excellent combination of high impact, cutting edge science, and a great social program in an interesting venue. Kevin Schug shares his thoughts about innovations in gas chromatography presented at this year's conference in Riva del Garda, Italy.
Jun 09, 2014
E-Separation Solutions
By LCGC Editors
When developing a separation, some fundamental choices need to be made on how we might achieve the separation we require - primarily the mode of chromatography used and the way in which we intend to control and optimise the retention and separation (selectivity) of analyte components.
May 15, 2014
E-Separation Solutions
By LCGC Editors
Many troubleshooting investigations in chromatography often don?t lead to a single causal factor. Often, the reason for problems or lack of method robustness are related to many small ?contributory factors? and this is particularly true of the problems associated with sample introduction in capillary Gas Chromatography.
May 08, 2014
LCGC North America
By LCGC Editors
Solid-phase extraction (SPE) is a versatile and reliable technique that is often used for sample cleanup and concentration. Kevin Schug offers some insight about SPE basics and achieving successful extractions.
Apr 17, 2014
E-Separation Solutions
By LCGC Editors
This blog attempts to provide an impartial guide to liner selection which is representative of the considerations in modern capillary GC.