Comparison of Edible Oils by GCxGC–TOF-MS and GC–High Resolution TOF-MS for Determination of Food Fraud: A "Foodomics" Approach - - Chromatography Online
Comparison of Edible Oils by GCxGC–TOF-MS and GC–High Resolution TOF-MS for Determination of Food Fraud: A "Foodomics" Approach


Special Issues
pp. 26-33

Here, a method to characterize edible oils and edible oil mixtures through fingerprinting and the isolation of individual analyte differences is reported. Aroma and flavor analytes in extra virgin olive, olive, peanut, grapeseed, and vegetable oils were sampled with headspace solid-phase microextraction (HS-SPME). The samples were analyzed with complementary gas chromatography (GC) systems; two-dimensional GC paired with time-of-flight mass spectro-metry (GC×GC–TOF-MS) and one-dimensional GC coupled to high resolution TOF-MS. These methods allowed for comparing edible oil varieties by their chromatographic fingerprints, characterizing the samples with the identification of individual analyte differences, differentiating oil mixtures from pure oil varieties with principal component analysis (PCA), and confirming analyte identities with accurate mass data.

Characterization of food products, including distinguishing differences, is important in the food industry. Differences that are intentionally introduced are of particular interest. The global marketplace has seen an increase in cases of food fraud, which is loosely defined as the deliberate misrepresentation of a product for the purpose of monetary gain, with cost estimates of these types of fraud at $10–15 billion dollars per year (1). Olive oil adulteration ranks near the top of all reported food fraud cases with common adulterations including the substitution of olive-derived oils with other less expensive edible oils or the mislabeling of regular olive oils as extra virgin olive oil (2).

These adulterations are often difficult for a consumer to detect, but can decrease health benefits and have the potential for unintended exposure to allergens — for example, by adulteration with nut oils. Detecting food fraud experimentally is also challenging because of the inherent variations of natural products and the wide range of potential methods of adulteration. Targeted analytical tools to screen for specific analytes or known adulterants have the risk of missing new or unanticipated mechanisms of food fraud. Nontargeted analytical methods, especially those that isolate individual analytes within a food matrix and characterize complex food products, are well-suited for addressing these challenges.

Gas chromatography (GC) is a well-established analytical approach used in the food industry for isolating individual analytes within a complex matrix. For many samples, one-dimensional GC is sufficient to isolate the components of the mixture, but as sample complexity increases so does the occurrence of coelution. One approach to handle increased complexity and analyte coelution is the use of comprehensive two-dimensional GC (GC×GC), which couples a complementary second separation dimension to the primary column and leads to an increase in the peak capacity, theoretically as high as the multiplicative of the individual peak capacities of each column. This technique has been shown to be a powerful method for analyzing food products (3).

Coupling GC separations with mass spectrometry (MS) provides a means for identifying the isolated analytes present in the food sample. When unanticipated analytes are present, identification can provide insight to the mode of adulteration. Time-of-flight (TOF) MS is especially beneficial for nontargeted analyses as it is capable of collecting full mass range data at fast acquisition rates and target analytes do not need to be specified before acquisition. Full mass range spectra can be library searched for identification and accurate mass information from high-resolution MS systems provides added confidence to identifications with formula computation capabilities. In this study, both one-dimensional (1D) and two-dimensional (2D) GC and both nominal and accurate mass MS systems were utilized, providing complementary and confirmatory information to characterize edible oils. These analytical tools have the potential to identify food fraud through differentiation of oil varieties and oil mixtures.


ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: Standardized Testing of Silica as a Base Material for Difficult Bonded-Phase Preparative Applications


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Seven Common Faux Pas in Modern HPLC


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Retention Time Variation Is Normal?


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: Special Issues,
Click here