Automated USP and EP GPC/SEC Analysis of Low Molecular Weight Heparin (LMWH) - - Chromatography Online
Automated USP and EP GPC/SEC Analysis of Low Molecular Weight Heparin (LMWH)


LCGC Asia Pacific
Volume 13, Issue 2

Daniela Held, PSS Polymer Standards Service GmbH, Mainz, Germany.

Introduction

LMWHs are defined as heparin salts having an average molecular weight of less than 8000 Da and for which at least 60% of all chains have a molecular weight less than 8000 Da. GPC/SEC is the method of choice to measure the molecular weight (molar mass) and the molecular weight fractions above/below a molecular weight limit. Both, the Pharmaeuropa (EP) and the US Pharmacopeia (USP), require GPC/SEC to characterize commercially available LMWHs.

Results


Figure 1
Although the calibration procedures described in the EP and USP are totally different, a dedicated GPC/SEC software can be used to analyse the heparin data in accordance with both standards precisely. Figure 1 shows the final results for the analysis of unknown low molecular weight heparin. PSS WinGPC Unity GPC/SEC software allows 2 markers to be set at 2000 and 8000 Da, to display the measured percent below 2000 Da, above 8000 Da and in between these values.


Table 1: Comparison of experimental conditions from USP and EP for the characterization of LMWH.
Of utmost importance is the y-axis of the result window. WinGPC Unity shows a true molar mass distribution with a w(log M) axis. Only this guarantees correct fractions above/below the molecular weight borders 2000 and 8000.3

References

1. USP Enoxaparin sodium http://www.usp.org/pdf/EN/USPNF/enoxaparinSodium.pdf

2. EP Low-Molecular-Mass (LMM) heparins Monograph 0828.

3. D. Held and P. Kilz; Quantification in LC and GC - A Practical Guide to Good Chromatographic Data [H.-J. Kuss/ S. Kromidas (eds.)], 271–302, Wiley-VCH, Weinheim (2009).

PSS Polymer Standards Service GmbH
In der Dalheimer Weise 5, D-55120 Mainz, Germany
tel. +49 6131 96239 41 fax +49 6131 96239 11
E-mail:
Website: http://www.polymer.de/

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: Standardized Testing of Silica as a Base Material for Difficult Bonded-Phase Preparative Applications


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Seven Common Faux Pas in Modern HPLC


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Retention Time Variation Is Normal?


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: LCGC Asia Pacific,
Click here