New Wave of Gas Chromatography - - Chromatography Online
New Wave of Gas Chromatography


Meeting Reports

Session 340, Room S404bc, 8:30 a.m.

This Monday morning session will be presided over by Milton L. Lee of Brigham Young University, who also arranged the session.

The session will open with introductory remarks from Lee, followed by his presentation, “Changing Faces of Gas Chromatography.” He will discuss the evolution of the technique and its instrumentation to “smart” GC instruments and methods.

Next, Stanley D. Stearns of Valco Instruments will present a talk titled “Resistively Heated Gas Chromatography.” His presentation will describe direct resistive heating using a nickel wire or nickel plating on the column with a temperature controller that employs sophisticated control algorithms.

The third presentation in the symposium will be given by Robert E. Synovec of the University of Washington and is titled “Advances in Instrumentation and Data Analysis Methods to Improve Peak Capacity in GC–TOFMS and GCxGC–TOFMS.” His talk will look at some recent advances in instrumentation development for the two techniques.

After a brief recess, Edward T. Zellers of the University of Michigan will present “A Microfabricated Comprehensive Two-Dimensional Gas Chromatograph (µGC X µGC).” Zellers will discuss the development and preliminary characterization of a microfabricated comprehensive 2D GC system that includes silicon micromachined components.

The final presentation in the session, titled “Properties of Thermal Gradient GC Separations,” will be given by H. Dennis Tolley of Brigham Young University. His presentation will address topics such as virtual column length, correction of imperfect separation, restriction of peak broadening over time, application to 2D separations, and on-column concentration of analytes.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: When Bad Things Happen to Good Food: Applications of HPLC to Detect Food Adulteration


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: HPLC for Characterization and Quality Control of Therapeutic Monoclonal Antibodies


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Can I Inject? Part I: Injecting in Mobile Phase


More LCGC Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: Meeting Reports,
Click here