Analysis of Wastewater in New York State Indicates Illicit Drug Consumption - - Chromatography Online
Analysis of Wastewater in New York State Indicates Illicit Drug Consumption


The Column
Volume 12, Issue 10, pp. 7

The study of sewage using chromatographic techniques is a rapidly expanding area that can provide insights into the consumption of illicit drugs. Measuring illicit drug concentrations can provide authorities with a close to real time identification of consumption trends and rates in specific geographical areas (1).

A team of scientists recently performed liquid chromatography–electrospray tandem mass spectrometry (LC–ESI–MS–MS) to determine illicit drug use in New York State (2). In this study, 24-hr composite wastewater influent, primary effluent, final effluent and sludge samples were collected daily for seven days from two wastewater treatment plants (WWTPs) in New York State and analyzed for the presence of selected illicit drugs (six drugs and eight metabolites). The concentration of illicit drugs determined in sewage sludge and wastewater effluent was used to calculate the total environmental emission from the WWTPs. Other markers such as caffeine, paraxanthin, nicotine and cotinine were used to predict the concentration of selected illicit drugs in wastewater.

The environmental emission of illicit drugs per capita from discharges from WWTPs was calculated to range from 0.38 mg/d/1000 people (MDEA) to 67.5 mg/d/1000 (EDDP). The emission rates for BEG, MAPT, MTD, MPH, MDMA ranged from 10.5 mg/d/1000 people to 20.5 mg/d/1000 people. MDA was the most abundant hallucinogen found in wastewater effluent at a mean concentration of 304 ng/L.

Co-author of the study, Bikram Subedi, postdoc research affiliate at Wadsworth Centre (Albany, New York) told LCGC: “Further research should involve investigating the stability of illicit drugs in wastewater matrices and also a comprehensive evaluation of their discharge to the receiving environment including agricultural land, surface water, and drinking water. The evaluation of the potential environmental health effects as a result of prolonged exposure to these contaminants is important.”

A similar study set up in Europe published recently revealed the findings of drug consumption trends in 42 European cities using liquid chromatography tandem mass spectrometry (LC–MS–MS) (1).

References
1. C. Ort et al. Addiction, DOI:10.1111/add.12570 (2014).
2. B. Subedi and K. Kurunthachalam, Environmental Science and Technology, DOI: 10.1021/es501709a (2014).

This story originally appeared in The Column. Click here to view that issue.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Sample Prep Perspectives | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments.
LATEST: UV Detector Problems


Perspectives in Modern HPLC | Michael W. Dong: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Superficially Porous Particles: Perspectives, Practices, and Trends


MS — The Practical Art | Kate Yu: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting | John Dolan: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: Problems with Large-Molecule Separations


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: The Column,
Click here