Beer Marinade Inhibits PAH Production

The Column
Volume 10, Issue 7, pp. 5

A team of scientists in Portugal and Spain have performed high performance liquid chromatography coupled with fluorescence detection (HPLC–FLD) to show that marinating pork meat in beer can reduce the levels of polycyclic aromatic hydrocarbons (PAHs) formed when grilled over charcoal. The study published in the Journal of Agricultural and Food Chemistry suggests a potential reduction in PAH levels of up to 50% compared with non-marinated meat.1

PAHs are found in a wide range of food products, particularly foods that have been smoked or chargrilled, and frequent consumption of these foods can pose a health risk. Lead author of the study Isabel Ferreira told The Column: “It is well known that the frequent consumption of charcoal grilled meat is associated with the increase of [an] individual’s chances of developing colorectal cancer. This relationship results from the presence of carcinogenic compounds such as PAHs and heterocyclic aromatic amines (HAAs). Thus, mitigation strategies to reduce the formation of those compounds during charcoal grilling are welcome.”

The team had previously investigated the effects of antioxidant containing drinks on the formation of HAAs, such as wine and green tea, but this is the f rst study to look at the effects of beer marinades on the activity of PAHs. Ferreira said: “Since free radicals are well known to be readily mopped up by antioxidants, several studies performed in recent years by our group explored the possibility of applying antioxidant-containing beverages, like tea, wine, and beer, to meat before grilling to reduce the formation of carcinogenic compounds, firstly the HAAs, and more recently PAHs. In this context we decided to explore the use of different types of beer.”

Pork meat was marinated in Pilsner beer, nonalcoholic Pilsner beer, or Black beer for four h at 5 ºC at a 1:1 (g/mL) ratio with no other ingredients. The prepared meat was then grilled over charcoal. Samples were taken and extracted for analysis. HPLC–FLD was performed to determine levels of PAHs remaining in each of the cooked samples.

The unmarinated pork meat samples contained an average of 20.57 ng PAHs per g of grilled meat, which dropped to 9.74 ng per gram after marination in Black beer, according to Ferreira. She said: “The reduction of carcinogenic compounds is higher than 50%. Thus, it is possible to obtain a healthier cooked food with improved sensory characteristics because beer marinades are tasty and improve meat tenderness.” — B.D.

Reference
1. I.M.P.L.V.O Ferreira et al., J. Agric. Food. Chem. 62, 2638–2643

This article is from The Column. The full issue can be found here.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: Avoiding Reversed-Phase Chromatography Problems Through Informed Method Development Practices: Choosing the Stationary-Phase Chemistry


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Seven Common Faux Pas in Modern HPLC


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: Estimating Resolution for Marginally Separated Peaks


More LCGC Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: The Column,
Click here