New LC–MS–MS Method to Detect Counterfeit Drugs - - Chromatography Online
New LC–MS–MS Method to Detect Counterfeit Drugs


The Column
Volume 10, Issue 11, pp. 9

Researchers at the Université de Montréal in Canada have developed and validated a new liquid chromatography tandem mass spectrometry (LC–MS–MS) method to identify compounds present in suspected counterfeit or even adulterated erectile dysfunction drugs. According to the study published in the Journal of Chromatography A, the method has now been introduced to the Inspectorate Laboratory Programme at Health Canada (Canada).1

The researchers applied LC–MS–MS to the analysis of 35 samples including: three legal tablets of Viagra, Cialis, and Levitra; six counterfeit Viagra tablets; four counterfeit Cialis; three counterfeit Levitra; nine tablets from unknown sources; eight herbal samples; and two gel capsules. The method took 10 min to perform.

Overall, 71 active ingredients and 11 natural ingredients were identified. The four most commonly found compounds were sildenafil, tadalafil, vardenafil, and icariin. The paper reports that the method was up to five times faster than high-performance liquid chromatography with UV (HPLC–UV) and gas chromatography coupled to mass spectrometry (GC–MS). – B.D.

Reference
1. P. Lebel, J. Gagnon, A. Furtos, and K. Waldron, Journal of Chromatography A 1343, 143–151 (2014).

This article is from The Column. The full issue can be found here

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Sample Prep Perspectives | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments.
LATEST: UV Detector Problems


Perspectives in Modern HPLC | Michael W. Dong: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Superficially Porous Particles: Perspectives, Practices, and Trends


MS — The Practical Art | Kate Yu: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting | John Dolan: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: Problems with Large-Molecule Separations


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: The Column,
Click here