EDCs alter US water quality - - Chromatography Online
EDCs alter US water quality

The Column
Volume 9, Issue 1

Previously unreported biological activity of endocrine disrupting chemicals (EDCs) has been detected in water samples from 14 states in the US by researchers at the National Cancer Institute, Maryland, USA.1 The findings demonstrate the presence of androgen and glucocorticoid in US water sources.

The reporting of EDCs in water sources is not new: The New York Times ran several articles on the issue in 2009.2 Researchers previously focused on the identification of contaminants but this new study concentrates on creating an assay for biological activity. This suggests that although levels of androgen and glucocorticoid have previously been undetected, there are biologically relevant concentrations of these chemicals present.

EDCs are chemicals that alter the functioning of an organism by interfering with the endocrine (hormone) system. This can affect aquatic ecosystems as well as human health. Estrogenic compound contamination has been associated with reproduction issues, cancer occurrence, obesity and thyroid metabolism.2 The origin of ECDs in water sources has been attributed to pharmaceutical waste disposal and increased use of prescription drugs by the general population. Anti-inflammatory drugs, classed as glucocorticoids, have a low recovery rate by water treatment plants and can enter water sources in the environment.

Dr Hager, co-author of the study, told The Column that currrent analysis and screening methods are: “expensive and not applicable for large‑scale screening” with approaches focusing on the identification of specific compounds rather than activity. The use of traditional chromatographic methods and analysis can identity known chemicals within samples, but not necessarily unknown or chemicals present at low concentrations. To fill this gap in analysis, the scientists designed a living cell‑based system that could be used to process a high throughput of samples.

Androgen and glucocorticoid have a similar method of changing cell behaviour. The hormones are taken up inside the cell where they bind to their partner receptors. Once partnered, the hormones are transported to the DNA of the cell, where they alter the expression of other hormones and proteins. The scientists exploited this capability to create a reporter system. In the presence of ECDs expression of green fluorescent protein (GFP) is activated. GFP is a commonly used reporter derived from the jellyfish Aequorea victoria, which on exposure to light glows a distinctive green colour. Therefore, when the cell system was exposed to androgen or glucocorticoid, the cells glowed green.

Water samples were prepared for analysis by fractionation using high performance liquid chromatography (HPLC); subsequently, each fraction was tested using the cell-based assay. Glucocorticoid activity was found in 27% of water source samples collected from 14 US states; and androgen activity was found in 35% of the samples. Environmental degradation and metabolic processes are thought to alter the structure of known ECDs producing new bioactive structures that are not contained on any databases. This poses a potential health hazard according to the authors of the study.1

The results of the investigation may be concerning, but it is the method that offers advancements in water quality analysis. In combination with fractionation methods, would it be possible to use the cell-based assay to improve water sample analysis alongside traditional approaches? According to Hager, the answer is yes: “Our technology could provide an approach for large scale screening to investigate any potential health concern,” he said.


References
1. E. Diamanti-Kandarakis et al, Endocrine Reviews
30(4), 293–342 (2012).
2. The New York Times website; Last accessed: 17th December 2012 <http://projects.nytimes.com/toxic-waters

 

This article first appeared in The Column. Click here to go to that issue.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 
Survey
How easy is it to implement a QbD approach to analytical method development?
How easy is it to implement a QbD approach to analytical method development?
Very easy
Fairly easy
Not easy
Very easy
11%
Fairly easy
46%
Not easy
43%
View Results
Source: The Column,
Click here