Forensic fingerprinting - - Chromatography Online
Forensic fingerprinting

The Column
Volume 8, Issue 20

Fingerprint analysis has been a standard method for forensic analysis and is used to identify suspects at the scene of a crime. Recent advances in next‑generation DNA sequencing technology have revolutionized the criminal justice system and has downgraded the importance of fingerprint analysis. It was previously considered that DNA evidence indicated the presence of an assailant at the scene of a crime, but this is no longer the case. The positioning of DNA material can be circumstantial in some cases and this is where recent advances in analytical chemistry instrumentation can enhance the power of fingerprint analysis.

A fingerprint is defined as an invisible impression composed of ridges and grooves left by an individual on a surface. Fingerprints are often incomplete and cannot be used for the automated identification protocols used in forensic investigations.1 However, human skin secretes a unique chemical signature that is thought to be influenced by environmental factors such as diet, chemical exposure and individual genetics.

A group of researchers1 published a study which exploited the unique properties of individual fingerprints to create a more detailed profiling method. Rather than simply observing the ridged patterns associated with unique exposure of the individual’s hands to their environment, the scientists analysed the chemical signature as a new parameter for analysis. The study aimed to identify fatty acids associated with specific fingerprints using gas chromatography–mass spectrometry (GC–MS). The group found that there were differences in the chemical signature associated with fingerprints when comparing individuals of different race and gender, specifically variation in the ratio of several fatty acid and methyl esters. There was additional evidence to suggest that other compounds mirrored this variability, however, further investigation is required to confirm this hypothesis. As a greater number of individuals are sampled and additional controls are implemented, it will become clearer if this will method will become commercialized.

1. S. Michalski et al, Forensic Sci, DOI: 10.1111/1556-4029.12010 (2012).

This story originally appeared in The Column. Click here to view that issue.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 
Survey
If you are you planning to attend HPLC2013 Amsterdam what is your main reason?
If you are you planning to attend HPLC2013 Amsterdam what is your main reason?
Sharing new techniques
Viewing the latest products and applications
Networking
Learning
Sharing new techniques
36%
Viewing the latest products and applications
27%
Networking
9%
Learning
27%
View Results
Source: The Column,
Click here