HPLC–MS–MS Detects Insecticide Degradates in Baby Food - - Chromatography Online
HPLC–MS–MS Detects Insecticide Degradates in Baby Food


The Column
Volume 12, Issue 10, pp. 8

Scientists from Emory University (Georgia, USA) have developed a new solid‑phase extraction (SPE) method to isolate four insecticide degradates from baby food for analysis by high performance liquid chromatography tandem mass spectrometry (HPLC–MS–MS)(1). The paper published in the Journal of Agricultural and Food Chemistry describes how the method can be applied to differentiate between exposure to insecticides or preformed degradates.

Analysts typically sample urine and test for the presence and concentration of organophosphorus and pyrethoid insecticide metabolites to determine insecticide exposure, assuming that there is a correlation between intake and excretion. One problem with this approach is that breakdown products can already be present on food and exposure can be overestimated. Samantha Radford, coauthor of the paper, told The Column: “Exposure scientists often quantify a person’s insecticide exposure by measuring urinary insecticide metabolites. This assessment relies on the presupposition that this person is exposed only to the parent compound and not to any insecticide metabolites preformed in the environment, which we term insecticide degradates. There are few studies exploring whether these preformed degradates exist in the environment, so we currently don’t know whether or not that is an accurate assumption."

The method was developed to measure degradates in baby food including malathion dicarboxylic acid [malathion]; 3,5,6-trichloro-2-pyridinol [chlorpyrifos, chlorpyrifos methyl] (TCPy); cis/trans-3-(2,2‑dichlorovinyl)-2,2‑dimethylcyclopropane-1-carboxylic acid [permethrin, cypermethrin, cyfluthrin]; and 3-phenoxybenzoic acid [general pyrethroid]. Two brands of baby food sold in the USA were sampled, and included green beans, carrots, peas, apples, bananas, and pears. Organic branded foods were used for method validation and spiked samples demonstrated method accuracy. Samples were prepared using SPE, before they were analyzed by HPLC–MS–MS with an electrospray ionization interface (ESA).

Recovery rates were between 80–120%. MDA, TCPy, and DCCA were found in all baby food, including some organic foods. Analytical degradation of insecticides was ruled out as being statistically insignificant. Radford said: “The method we present in Journal of Agricultural and Food Chemistry causes no statistically significant analytic degradation; therefore, we can feel confident that any degradate we find comes from preformed insecticide metabolites in the food and not from degradates formed during the extraction or chromatographic process.” She added: ”As far as advantages go, the main one is that there are very few methods currently available to extract these compounds from food. Of those that exist, we do not know if they cause bias due to analytic degradation of parent pesticide.“ — B.D.

Reference
1. S.A. Radford, P. Panuwet, R.E. Hunter, D.B. Barr, and P.B. Ryan, Journal of Agricultural and Food Chemistry DOI: 10.1021/jf500779a (2014).

This story originally appeared in The Column. Click here to view that issue.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: Standardized Testing of Silica as a Base Material for Difficult Bonded-Phase Preparative Applications


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Seven Common Faux Pas in Modern HPLC


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Retention Time Variation Is Normal?


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: The Column,
Click here