Principal Component Analysis with LC–MS Enhances Natural Drug Discovery Process - - Chromatography Online
Principal Component Analysis with LC–MS Enhances Natural Drug Discovery Process


The Column
Volume 10, Issue 4

Scientists in Malaysia have developed a useful metabolomics approach that could aid analysts working in natural drug discovery. The team applied liquid chromatography–mass spectrometry (LC–MS) coupled with principle component analysis (PCA) to screen more than 4000 natural extracts for novel photosensitizer drugs.1

Photodynamic therapy (PDT) is an alternative treatment to chemotherapy that has high selectivity, no drug resistance, and is less invasive. The therapy combines photosensitizers with a specific wavelength of light to kill cancer cells. Photosensitizers localize to the site of a tumour and are subsequently excited with a light source to release cytotoxic reactive oxygen species that kill the local cells. The targeted impact of the drug on excitation reduces the impact on healthy tissues, a major side effect of standard chemotherapy.

According to the paper there are only a small number of photosensitizers available. The US Food and Drug Administration (US FDA) has approved the use of porfimer sodium solution (marketed as Photofrin) for use in certain cancers.2 However, it only has limited efficacy in treating deep-seated lesions because it can only weakly absorb the red light that is able to penetrate into deep tissue1. Therefore, there is a demand for more effective compounds.

A pool of more than 4000 samples from natural extracts, collected from collaborating research groups across Malaysia, were screened. Extracts were selected on their ability to decrease the number of viable promyelocytic leukemia cells in vitro by 50% or more when illuminated compared to a control experiment in the dark.

The LC–MS profiles of 278 extracts that showed photocytoxic activity were analyzed with PCA. Compounds of the same structure were more likely to cluster together and be easily compared to known compounds. Outliers were cross-referenced against a database of common photosensitizers. Two novel photosensitizer compounds were identified using the approach.

PCA helped to overcome the problem of chemical redundancy and was able to rapidly identify the top 10% most suitable extracts, according to the authors. They concluded that these extracts could be prioritized for further investigation without having to know any prior information about the studied sample, which could save time and cut costs compared to conventional techniques.

 

References
1. Hong Boon Lee et al, Analytical Chemistry, DOI: 10.1021/ac403709a(2014).
2. National Cancer Institute at the National Institute of Health (USA): http://www.cancer.gov/cancertopics/factsheet/Therapy/photodynamic  [Last accessed: February 14, 2014].

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Sample Prep Perspectives | Ronald E. Majors:

LCGC Columnist Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments in existing technology lines.

LATEST: The Role of Selectivity in Extractions: A Case Study

History of Chromatography | Industry Veterans:

With each installment of this column, a different industry veteran covers an aspect of the evolution and continued development of the science of chromatography, from its birth to its eventual growth into the high-powered industry we see today.

LATEST: Georges Guiochon: Separation Science Innovator

MS — The Practical Art| Kate Yu:
Kate Yu is the editor of 'MS-The Practical Art' bringing her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers.

LATEST: Mass Spectrometry for Natural Products Research: Challenges, Pitfalls, and Opportunities


LC Troubleshooting | John Dolan:

LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan, Vice President of LC Resources and world renowned expert on HPLC, is able to highlight common problems and provide remedies for them.

LATEST: LC Method Scaling, Part I: Isocratic Separations

More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: The Column,
Click here