Wednesday Morning Session: Energy, Petroleum, and Biofuels: Advances in Sample Preparation and MS Interface Design - - Chromatography Online
Wednesday Morning Session: Energy, Petroleum, and Biofuels: Advances in Sample Preparation and MS Interface Design


Meeting Reports

This Wednesday morning session (WOA) will take place in Exhibit Hall AB from 8:30–10:30 a.m. Mark Lowenthall of the National Institute of Standards and Technology (NIST) will preside.

The first talk in this session is titled “Combining Metal Ion Complexation and Ultrahigh Resolution Mass Spectrometry for the Selective Analysis of Nitrogen Compounds in Asphaltenes.” Wolfgang Schrader of the Max-Planck Inst. für Kohlenforschun in Mülheim / Ruhr, Germany will present.

Next, Mckay Easton of Purdue University in West Lafayette, Indiana will present. Easton’s talk is titled “A Combined Experimental and Computational Study on the Reaction Pathways of Fast Pyrolysis of Cellobiose.”

Michael T. Cheng of Chevron Research in Richmond, California will talk next. Cheng’s presentation is titled “Detailed Characterization of Crude Oil and Its Fractions, Is Mass Spectrometry Sufficient?”

After Cheng, Steven M. Rowland of Florida State University in Tallahassee, Florida will present. Rowland’s talk is titled “Separation-Enhanced Characterization of Oxygenated Petroleum Compounds by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS).”

Arne Ulbrich of the University of Wisconsin in Madison, Wisconsin is next with a talk titled “Characterization and Quantification of Fermentation Inhibitors in Biomass Hydrolysates for Biofuel Production.”

Aviv Amirav of Tel-Aviv University in Tel-Aviv, Israel and Aviv Analytical Ltd. will present the last talk in this session. Amirav’s talk is titled “Isomer Distribution Analysis for Improved Hydrocarbon Mixtures Characterization.”

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch | Ronald E. Majors: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: Standardized Testing of Silica as a Base Material for Difficult Bonded-Phase Preparative Applications


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: Seven Common Faux Pas in Modern HPLC


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Retention Time Variation Is Normal?


More LCGC Chromatography-Related Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: Meeting Reports,
Click here