Updates on hypoadrenocorticism - The lack of a stress leukogram in dogs with gastrointestinal signs may signal this potentially life-threatening disease. This review will help ensure that you aren't o
Updates on hypoadrenocorticism
The lack of a stress leukogram in dogs with gastrointestinal signs may signal this potentially life-threatening disease. This review will help ensure that you aren't overlooking other clinical signs and that you know the latest about diagnosing and treating canine hypoadrenocorticism.


VETERINARY MEDICINE


CLINICAL FINDINGS

Clinical signs and the findings from a physical examination, complete blood count (CBC), serum chemistry profile, and urinalysis vary depending on the type of deficiency present.

Glucocorticoid deficiency


Table 1: Clinical Signs in Dogs with Glucocorticoid or Glucocorticoid and Mineralocorticoid Deficiency*
Glucocorticoids are important for maintaining homeostasis, especially during stress. They play a role in metabolizing glucose, fats, and proteins; stimulating erythropoiesis; and regulating the immune system.1,6 The most common clinical signs of glucocorticoid deficiency include lethargy, weakness, anorexia, weight loss, vomiting, and diarrhea (Table 1).4,7,11 Other less common clinical signs include polyuria and polydipsia, exercise intolerance, and seizures.7,12 Clinical signs may be intermittent and associated with stressful events such as boarding, grooming, and medical evaluation. Physical examination findings in dogs with glucocorticoid deficiency are nonspecific and can include weakness and thin body condition.6

Gastrointestinal (GI) signs are common in dogs with glucocorticoid deficiency because glucocorticoids are important for maintaining GI mucosal health, GI motility, and colonic sodium absorption.1,7,8 Hypocortisolemia may potentiate mucosal ulceration and hemorrhage as a result of decreased vascular integrity.6 Exercise intolerance or seizures may develop if severe hypoglycemia occurs; however, hypoglycemia is typically mild.12


Table 2: Laboratory Findings and Their Proposed Pathogenesis in Dogs with Glucocorticoid Deficiency or Glucocorticoid and Mineralocorticoid Deficiency*
Common findings on a CBC include normocytic, normochromic, nonregenerative anemia and a lack of a stress leukogram (Table 2).7 Glucocorticoids, along with other hormones, stimulate erythropoiesis, so glucocorticoid deficiency may result in anemia. GI hemorrhage can further contribute to anemia in dogs with hypocortisolemia.6,7,11 A lack of a stress leukogram most commonly manifests as a normal or increased lymphocyte count with or without eosinophilia.5,6

Serum chemistry profile abnormalities in dogs with glucocorticoid deficiency include hypoalbuminemia, hypocholesterolemia, hypoglycemia, and mild hyponatremia.6,7 Impaired absorption of nutrients, protein-losing enteropathy, and decreased albumin production may contribute to the hypoalbuminemia.13 Hypocholesterolemia is thought to result from altered lipid absorption.6 Hypoglycemia may be due to blunted gluconeogenesis and increased glucose uptake and use by peripheral tissues.6,12 Mild hyponatremia may develop because of decreased vasopressin secretion and blunted colonic sodium absorption. In healthy dogs, glucocorticoids inhibit vasopressin release; therefore, with glucocorticoid deficiency, inappropriate vasopressin secretion may cause water retention and result in a dilutional hyponatremia.1,7


ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters
Global E-newsletters subscribe here:




 

LCGC COLUMNISTS 2014

Column Watch: Ron Majors, established authority on new column technologies, keeps readers up-to-date with new sample preparation trends in all branches of chromatography and reviews developments. LATEST: When Bad Things Happen to Good Food: Applications of HPLC to Detect Food Adulteration


Perspectives in Modern HPLC: Michael W. Dong is a senior scientist in Small Molecule Drug Discovery at Genentech in South San Francisco, California. He is responsible for new technologies, automation, and supporting late-stage research projects in small molecule analytical chemistry and QC of small molecule pharmaceutical sciences. LATEST: HPLC for Characterization and Quality Control of Therapeutic Monoclonal Antibodies


MS — The Practical Art: Kate Yu brings her expertise in the field of mass spectrometry and hyphenated techniques to the pages of LCGC. In this column she examines the mass spectrometric side of coupled liquid and gas-phase systems. Troubleshooting-style articles provide readers with invaluable advice for getting the most from their mass spectrometers. LATEST: Radical Mass Spectrometry as a New Frontier for Bioanalysis


LC Troubleshooting: LC Troubleshooting sets about making HPLC methods easier to master. By covering the basics of liquid chromatography separations and instrumentation, John Dolan is able to highlight common problems and provide remedies for them. LATEST: How Much Can I Inject? Part I: Injecting in Mobile Phase


More LCGC Columnists>>

LCGC North America Editorial Advisory Board>>

LCGC Europe Editorial Advisory Board>>

LCGC Editorial Team Contacts>>


Source: VETERINARY MEDICINE,
Click here