Scientists from Hangzhou Dianzi University and the Zhejiang Provincial Department of Public Security, both in Hangzhou, China, recently tested a metal–organic framework (MOF)-based system for extracting benzodiazepines (BZPs) from urine. Their findings were published in the Journal of Chromatography A (1).
Benzodiazepines (BZPs) are psychiatric drugs typically used to treat panic, anxiety, and sleep disorders. A type of depressant, BZPs are depressants that produce sedation and hypnosis, relieve anxiety and muscle spasms, and reduce seizures (2). The most common BZPs include Valium, Xanax, and Klonopin, among others. While these substances have their uses, prolonged BZP use can lead to constipation, memory impairment, and other side effects; additionally, their wide availability and abuse can typically result in dependence and addiction while increasing crime rates. As such, a sensitive method for monitoring BZPs in biological samples must be developed, especially for criminal and clinical examinations.
Metal–organic frameworks (MOFs) are crystalline compounds made up of metal ions or clusters coordinated to often rigid organic molecules to form one-, two-, or three-dimensional structures that can be porous (3). They have also been viewed as promising sample pretreatment materials; however, powdered MOF performance improvement is often hindered by their aggregation and difficult recovery. To rectify this, the scientists used a biodegradable lightweight spherical aerogel for support in in situ growth of copper-based MOFs. Iron (III) oxide (Fe3O4) nanoparticles were also incorporated to achieve magnetic properties. This also led to hybrid aerogel spheres containing MOF-199 supported on magnetic oxidized cellulose nanofiber/carboxymethyl chitosan (MOF-199@mag-CNF/CMC) being fabricated.
In this study, the effects of Fe3O4 loading amount and organic-ligand concentration on the properties (spherical geometry and mechanical strength) of hybrid aerogel spheres were studied. Further, their potential application in BZP extraction from urine samples prior to liquid chromatography–mass spectrometry (LC–MS) was also evaluated. The highly dispersed MOF-199 crystals on spherical aerogel managed to almost completely overcome the bare aerogel spheres’ inherent structural shrinkage. Due to their highly specific surface area, high porosity, having oxygen groups present, and moderate polarity, MOF-199 effectively interacted with BZPs. The MOF crystals also improved the extraction ability of aerogel spheres for BZPs. As such, the MOF-199@mag-CNF/CMC aerogel spheres were deemed robust and capable of withstanding repeated use for at least eight consecutive extraction cycles.
Additionally, parameters influencing extraction and desorption were also comprehensively investigated. Under optimal conditions, this method provided a wide linear range of 0.1–10 µg/L (R2 > 0.995) and good precision (2.8–6.7% for intra-day; 1.9–7.8 % for inter-day). The limits of detection and quantification ranged from 0.02 to 0.11 µg/L and from 0.06 to 0.33 µg/L, respectively. When spiked with three concentrations of BZPs, the urine sample recoveries ranged from 73.9–114.1%. This proposed method, based on the scientists’ findings, proved simple, sensitive, and eco-friendly, allowing them to be used for future BZP determination from urine for clinical and forensic examinations.
(1) Zhang, S.; Liu, H.; Fu, D.; Zhao, H.; Zhang, D.; Lü, T. Spherical Cellulose/Chitosan Aerogel–Supported MOF-199 for the Magnetic Solid-Phase Extraction of Benzodiazepines from Urine. J. Chromatogr. A 2024, 1735, 465347. DOI: 10.1016/j.chroma.2024.465347
(2) U.S. DEA. Benzodiazepines. U.S. Department of Justice 2024. https://www.dea.gov/factsheets/benzodiazepines (accessed 2024-9-18)
AI-Powered Precision for Functional Component Testing in Tea Analysis
October 11th 2024Analyzing functional foods reveals numerous health benefits. These foods are rich in bioactive compounds that go beyond basic nutrition, boosting the immune system and improving overall wellness. However, analyzing these compounds can be challenging. This article discusses AI algorithms to support automated method development for liquid chromatography, simplifying the process, enhancing labor efficiency, and ensuring precise results, making it accessible to non-experts for tea analysis.
Advanced LC–MS Analysis for PFAS Analysis in Eggs
October 11th 2024The European Commission's regulation on maximum levels for certain contaminants in food highlights the need for precise and reliable methods to quantify per- and polyfluoroalkyl substances (PFAS) in various food matrices. This article discusses development and validation of a robust method for analyzing 21 PFAS compounds in chicken eggs using solid-phase extraction (SPE) and liquid chromatography–mass spectrometry (LC–MS).
New Algorithm Created for Detecting Volatile Organic Compounds in Air
October 9th 2024Scientists from Institut de Combustion, Aérothermique, Réactivité et Environnement (ICARE-CNRS) in Orléans, France and Chromatotec in Saint-Antoine, France recently created a new algorithm for detecting volatile organic compounds (VOCs) in ambient air.