May 8th 2024
Yelena Sapozhnikova from the United States Department of Agriculture spoke to The Column about her innovative research investigating PFAS in plastic food storage bags using targeted and non-targeted liquid chromatography–tandem mass spectrometry.
The Durian Tang: Investigating the World’s Smelliest Fruit
December 5th 2017The durian fruit is notorious for its unpalatable aroma, and yet the fruit is incredibly popular throughout Southeast Asia and amongst travellers. Holding the title of “the world’s smelliest fruit” attracts attention including that of Martin Steinhaus from the Aroma Research Group at the Deutsche Forschungsanstalt für Lebensmittelchemie (German Research Center for Food Chemistry). He spoke to The Column about his group’s research into the compounds responsible for the fruit’s uniquely unpleasant aroma.
Characterizing Red Chicory Polyphenols
November 7th 2017Polyphenols are a well-known group of antioxidants widely diffused as secondary metabolites in plants, vegetables, and fruit. The Column spoke to Nicola Marchetti from the Department of Chemistry and Pharmaceutical Sciences at the University of Ferrara in Ferrara, Italy, about his research into the characterization of polyphenols in red chicory using high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS).
Characterizing Polyphenols in Food Using Chromatography
October 10th 2017There is a growing interest in polyphenols because of their noticeable antioxidant properties and their potential contribution to the defence against oxidative stress and protection against cardiovascular diseases and cancers. Oscar Núñez from the Department of Chemical Engineering and Analytical Chemistry at the University of Barcelona in Barcelona, Spain, has been working since 2010 in the analysis of polyphenols by capillary electrophoresis (CE), liquid chromatography (LC), mass spectrometry (MS), and chemometric techniques to achieve the characterization, classification, and authentication of natural products in the prevention of frauds. He recently spoke to The Column about this research.
Ensuring the Safety of the Food Supply: Speeding Up Arsenic Speciation Analysis
October 1st 2017Speciation analysis of elemental contaminants in food and beverages has received a lot of attention in recent years. Recent regulations limit inorganic arsenic, taking into account that arsenic toxicity is dependent on the species present. Thus, the analysis procedure needs to be able to differentiate inorganic from organic arsenic forms. Liquid chromatography–inductively coupled plasma–mass spectrometry (LC–ICP-MS) is commonly used for the separation and detection of arsenic species, with the most widely used implementation based on ion exchange and characterized by relatively long run times. Testing of increasing sample numbers means that analysis speed becomes a focal point for potential improvements. We developed a method based on ion interaction chromatography, allowing a reduction in run times to
Determination of Cannabinoid Content and Pesticide Residues in Cannabis Edibles and Beverages
October 1st 2017As a result of the rapid growth of the cannabis industry, many testing laboratories are looking for efficient, reliable, and cost-effective analytical methods to analyze chemical residues, such as pesticides, mycotoxins, solvent residues, terpenes, and heavy metals, as well as cannabinoid concentration in cannabis-infused edibles and beverages. In this article, QuEChERS (quick, easy, cheap, effective, rugged, and safe), a sample preparation technique widely adopted in the food testing industry, is introduced to the discipline of forensic testing as a viable method for the extraction of pesticides and cannabinoids in various complex sample matrices. The claimed amounts of cannabinoids versus the actual amounts are compared, as well as the pesticide residue levels in edible and beverage samples.
Determination of α-Dicarbonyls in Wines Using Salting-Out Assisted Liquid–Liquid Extraction
October 1st 2017A method based on salting-out assisted liquid–liquid extraction for the analysis of α-dicarbonyls in wines was developed. The sample preparation procedure consists of a single step, involving the simultaneous extraction and derivatization of the analytes using an o-phenylenediamine–acetonitrile solution with sodium chloride as the salting-out agent. The obtained organic phase is collected and directly analyzed by liquid chromatography with spectrophotometric detection. The studied α-dicarbonyls were determined in eight wines. The developed methodology substantially reduces the complexity of the sample matrix, which is a very important aspect in routine analysis, especially to ensure long-lasting and reliable functioning of the chromatographic systems, while being a new and attractive methodology for the analysis of α-dicarbonyls.
Determining Chloride and Sugars in Food Samples Using HPLC
September 18th 2017Accurate quantification of sugars in saline solution is now possible using a new high performance liquid chromatography (HPLC) method. The Column spoke to Abdelrahman Saleh Zaky from the School of Biosciences at the University of Nottingham (Nottingham, UK) about this method.
Selecting the Best HPLC Column for Carbohydrate Analysis of Food Samples
September 12th 2017Food carbohydrate content is routinely analyzed to ensure food quality and taste. Over the years many analytical techniques, including thin-layer chromatography (TLC), enzymatic analysis, and gas liquid chromatography (GLC), have been developed that allow qualitative and quantitative analysis of sugars, organic acids, and alcohol in food. Amongst these, ion‑moderated partitioning high performance liquid chromatography (HPLC) has emerged as a very valuable tool and has been used in thousands of published studies. This article describes the various considerations for selecting and optimizing the use of ion-moderated partitioning HPLC analytical columns for carbohydrate analysis in various types of food samples.
Olive Oil Quality and Authenticity: Recent Improvements in Sample Preparation and GC–FID Analysis
September 12th 2017The growing popularity of extra virgin olive oil (EVOO), thanks in part to its presumed health benefits, has resulted in an increased incidence of product adulteration to achieve higher financial gains. This adulteration, through dilution with less expensive oils, has created demand for product authenticity testing. Olive oil testing based on traditional methods is slow, labour-intensive, and requires large amounts of organic solvents. This article reviews the challenges in the accurate analysis of olive oil and discusses new methods that can improve this testing.
Novel Metabolomics GC Method for Olive Oil Analysis
August 22nd 2017A method to determine the quality of olive oil has been developed using a novel atmospheric pressure chemical ionization (APCI) source in combination with gas chromatography (GC) coupled to hybrid quadrupole time-of-flight mass spectrometry (QTOF-MS) and a metabolomics strategy.
Testing Foods for Pesticides Using LC–MS/MS and SWATH Acquisition
August 22nd 2017Food testing laboratories worldwide are responsible for checking the presence of regulated pesticide residues on food products because these chemicals can be harmful to health and the environment. These laboratories have traditionally relied on gas chromatography coupled with mass spectrometry (GC–MS) for rapid and reliable pesticide detection in large sample numbers. However, changing regulations and increasingly diverse pesticides are driving the need for alternative liquid chromatography tandem mass spectrometry (LC–MS/MS)- based methods for comprehensive screening.
Detection and Characterization of Extractables in Food Packaging Materials by GC–MS
July 1st 2017In this study, general extract screening of food storage materials was done with nontargeted analytical methods to understand what analytes could potentially leach into food or beverages. GC and mass spectral deconvolution effectively separated analytes within the complex mixture and TOF-MS provided full mass range spectral data for identification. This workflow can be used for confident characterization of components present as extractables from food packaging materials.
Determination of Sophisticated Honey Adulteration with LC–IRMS
July 1st 2017Honey is a high-value commodity, whose quality is defined both by its botanical and geographical origin. This generates a strong consumer demand for certain, premium-priced products, which have become the target for adulterations. A useful tool to detect the addition of sugar to honey products is based on the well-documented difference in δ13C values between C3 (natural honey) and C4 (added sugar) plants. Coupling high performance liquid chromatography (HPLC) with isotope ratio mass spectrometry (LC–IRMS) has the unrivaled advantage of the simultaneous determination of δ13C values from glucose, fructose, di-, tri-, and oligo-saccharides, allowing the detection of more sophisticated honey adulteration with a simple user-friendly analytical system.
Flavour Profiling of Beverages Using Probe-Based Sorptive Extraction and Thermal Desorption–GC–MS
July 1st 2017This study shows that the organic compounds giving rise to the flavour of a variety of beverages can be identified by high-capacity sorptive extraction using PDMS probes, with analysis by thermal desorption–GC–MS.
The Use of Extraction Technologies in Food Safety Studies
March 1st 2017Traditional extraction methods for food samples, such as liquid-liquid extraction and Soxhlet extraction, are often time-consuming and require large amounts of organic solvents. Therefore, one of the objectives of analytical food safety studies currently has been the development of new extraction techniques that can improve the accuracy and precision of analytical results and simplify the analytical procedure.
Non-Targeted Screening Approaches for Food
February 21st 2017Non-targeted screening approaches are an essential element of food safety strategies, detecting novel or unexpected food contaminants and adulterants. However, the development and implementation of generalized and non-targeted screening workflows for food matrices is challenging. The inherent sample complexity and diversity as well as large analyte concentration ranges represent significant obstacles.
Automating Mycotoxin Analysis in Beverages
February 21st 2017The analysis of hazardous mycotoxins is crucially important in food to ensure the health of humans and animals. Here, a simple and fast analysis including the sample preparation and purification of mycotoxins within food is presented. Ten different mycotoxins were investigated simultaneously in 14 min. The method was applied to the analysis of mycotoxins in apple juice, grape juice, and two different batches of the same branded beer.