Gas Chromatography (GC)

Nov 09, 2015
The Column
Jack Cochran’s new column “Practical GC” aims to provide readers with practical advice and new experimental evidence for how to get the best results from their gas chromatography (GC) systems. The first article in a series on split injection GC focuses on the advantages of using “shoot-and-dilute” GC.
Nov 01, 2015
LCGC North America
Dead-volume effects can cause serious trouble for chromatographers. But if you understand what dead volume is and how it affects chromatographic results, you can take control of it.
Oct 05, 2015
The Column
By LCGC Editors
The Essentials: Optimizing Sample Introduction for Headspace GC
Oct 01, 2015
Special Issues
A method based on thermal desorption with gas chromatography–time-of-flight mass spectrometry (GC–TOF-MS) can elucidate how key volatiles vary with the size of the melon pieces. Such analytical information is of value in efforts to improve the quality and safety of ready-to-eat foods.
Oct 01, 2015
LCGC North America
A look at the the operation and maintenance of split-vent traps.
Aug 01, 2015
LCGC Europe
Ionic liquids (ILs) have become recognized in gas chromatography (GC) as stable and highly polar stationary phases with a wide application range. Having customizable molecular structures, ILs also offer a particular tunability that provides additional selectivity, and therefore may improve separation for neighbouring analytes. This article presents specific properties of IL phase capillary GC columns, including polarity scale and inner surface morphologies of IL columns. Application of IL phases in achiral and chiral GC, and multidimensional GC, are highlighted.
Jul 01, 2015
LCGC North America
Some insights into the principles and practice of implementing and improving on methods to quantitate cyanide at trace concentration levels in human blood.
Jul 01, 2015
LCGC North America
FID continues to play a crucial role for all types of gas chromatography, so it is important to understand how to use it effectively.
May 06, 2015
The Column
Solid-phase microextraction (SPME) coupled with comprehensive two-dimensional gas chromatography and time-of-flight mass spectrometry (GC×GC–TOF-MS) can be used to detect trace-level fungicides and compounds responsible for undesirable attributes known as “organoleptic faults” in wine. This article explains more.
May 01, 2015
Special Issues
The main objective of this study was to evaluate the capabilities of gas chromatography (GC) with time-of-flight mass spectrometry (MS) for screening pesticides in fruits and vegetables using a purpose-built accurate-mass database.