In a recent study out of Boehringer Ingelheim Animal Health USA Inc. in North Brunswick, New Jersey, Daoli Zhao and Abu M. Rustum investigated cloruson and its related substances using an original ion-paired reversed phase ultraperformance liquid chromatography (IP-UHPLC) method. Their findings were published in the Journal of Pharmaceutical and Biomedical Analysis (1).
Ivermectin tablet medication | Image Credit: © Soni's - stock.adobe.com
Clorsulon, also known as 4-amino-6-(1,2,2-trichloroethenyl)-benzene-1,3-disulfonamide, is an anthelmintic agent that is typically used alongside ivermectin to treat and control internal parasites and adult liver flukes (Fasciola hepatica, Fasciola magna and Fasciola gigantica) in sheep and cattle. Usually delivered as a suspension or in injectable forms, clorsulon inhibits parasite enzyme systems, which is the primary source of energy in flukes. Clorsulon is shown to be more effective against mature flukes, killing adult flukes within sheep at rates of 98% based on fecal egg counts, 99% based on the postmortem studies and 100% based on dictyocaulus filaria larval counts.
To determine clorsulon and its related substances, the scientists developed and validated a rapid ion-paired reversed phase ultraperformance liquid chromatography (IP-UHPLC) method. The new IP-UHPLC showed sample analysis times that were approximately 65% less than the current USP HPLC method for clorsulon, all while showing significantly improved selectivity and sensitivity. Stress degradation studies were conducted under International Council of Harmonization (ICH)-prescribed guidelines, and the method was said to be easily implemented for routine or non-routine analysis of clorsulon API (active pharmaceutical ingredient) samples. These experiments were performed in bulk drug substances batches of clorsulon with a short octadecyl column.
The analytes were eluted with a gradient elution on a Acquity UPLC® BEH C18 column (50 mm × 2.1 mm i.d., 1.7 µm particle size). Column temperature was maintained at 55 °C, and all analytes were monitored using UV detection at 268 nm. Two mobile phases were used in the experiment, mobile phase A constituting 3 mM tetrabutylammonium hydroxide in H2O and mobile phase B constituting acetonitrile/methanol (50/50, v/v), respectively.
All analytes of interest were separated to acceptable levels within 5 minutes. They were all quantitated against an external reference standard of cloruson, and the chemical structures of clorsulon’s degradation products were proposed based on two-dimensional UHPLC-MS data. With these findings, the IP-UHPLC method was successfully validated and shown to be accurate, sensitive, robust, and specific.
(1) Zhao, D.; Rustum, A. M. Determination of Clorsulon and Its Related Substances in Commercial Bulk Drug Substance Batches By a Rapid Ion-Pair UPLC Method. J. Pharm. Biomed. Anal. 2024, 239, 115896. DOI: https://doi.org/10.1016/j.jpba.2023.115896
Carol Robinson Awarded 2024 Lifetime Achievement European Inventor Award
July 24th 2024Carol Robinson of the University of Oxford has received the European Inventor Award 2024 for Lifetime Achievement from the European Patent Office for her work bringing mass spectrometry to structural biology.
Microseparations and Analysis Covered at HPLC 2024
July 23rd 2024At HPLC 2024 in Denver, Colorado, various sessions will be led by experienced scientists, covering different aspects of chromatography techniques and maximizing their effectiveness. Here is some information about tomorrow’s sessions.
Automated LC Method Development: An HTC-18 Interview with Bob Pirok
July 23rd 2024At HTC-18 in Leuven, Executive Editor of LCGC International, Alasdair Matheson, spoke to this year’s winner of the 2024 HTC-18 Innovation Award, Bob Pirok from the University of Amsterdam, about his innovative research on automated LC method development.
Carol Robinson Awarded 2024 Lifetime Achievement European Inventor Award
July 24th 2024Carol Robinson of the University of Oxford has received the European Inventor Award 2024 for Lifetime Achievement from the European Patent Office for her work bringing mass spectrometry to structural biology.
Microseparations and Analysis Covered at HPLC 2024
July 23rd 2024At HPLC 2024 in Denver, Colorado, various sessions will be led by experienced scientists, covering different aspects of chromatography techniques and maximizing their effectiveness. Here is some information about tomorrow’s sessions.
Automated LC Method Development: An HTC-18 Interview with Bob Pirok
July 23rd 2024At HTC-18 in Leuven, Executive Editor of LCGC International, Alasdair Matheson, spoke to this year’s winner of the 2024 HTC-18 Innovation Award, Bob Pirok from the University of Amsterdam, about his innovative research on automated LC method development.