Researchers at Universidade da Coruña in Zapateira, Spain have developed a new method for determining benzalkonium chloride (BAK) in pharmaceutical formulations using mixed-mode chromatography (1). The team observed a U-shaped retention behaviour based on mixed-mode reversed-phase–hydrophilic interaction liquid chromatography (HILIC) for BAK using a core–shell column functionalized with biphenyl groups.
In the study, the bimodal retention was observed for the four BAK homologues, and the data were adjusted to polynomial equations, which allowed for modelling and predicting the U-shaped retention. The method was validated by analyzing cutaneous, otic, and ophthalmic formulations with different active pharmaceutical ingredients and excipients. The proposed method has several advantages, including low sample volume and short analysis time, and good analytical performance was obtained.
Published in Talanta, the research reports that the U-shaped retention was dependent on the chemical structure of the analyte with mixed functionality and on the high selectivity of the chromatographic column. The salt concentration, anion and cation of the salt, and pH in the mobile phase were studied to understand their influence on the two retention modes. Linear relationships between the retention factors of the four homologues were found in a wide range of %acetonitrile when the salt and triethylamine concentration, pH, and nature of salt were changed. The differences found in the retention of the homologues, when increasing the alkyl chain length, were more significant in the reversed-phase mode because of predominant hydrophobic interactions.
Overall, the study highlights the importance of developing new chromatographic methods for the analysis of ionizable compounds such as BAK, and the potential of mixed-mode chromatography for pharmaceutical applications. The authors suggest that the proposed method could be further optimized and applied to other types of pharmaceutical formulations.
(1) Prieto-Blanco, M. C.; Planas-Franco, A.; Muniategui-Lorenzo, S.; González-Castro, M. J. Mixed-Mode Chromatography of Mixed Functionalized Analytes as the Homologues of Benzalkonium Chloride. Application to Pharmaceutical Formulations. Talanta 2023, 255, 124228. DOI: 10.1016/j.talanta.2022.124228
LC–MS/MS-Based System Used to Profile Ceramide Reactions to Diseases
April 26th 2024Scientists from the University of Córdoba in Córdoba, Spain recently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) to comprehensively profile human ceramides to determine their reactions to diseases.
High-Throughput 4D TIMS Method Accelerates Lipidomics Analysis
April 25th 2024Ultrahigh-pressure liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) had been previously proposed for untargeted lipidomics analysis, but this updated approach was reported by the authors to reduce run time to 4 min.
Traditional Chinese Medicine’s Effects on Liver Cancer Measured Using New UHPLC–QTOF-MS System
April 22nd 2024Scientists from Anhui University of Chinese Medicine in Hefei, China recently investigated the mechanisms behind what makes huachansu tablets, a type of traditional Chinese medicine (TCM), effective against liver cancer.