
- Special Issues-12-01-2014
- Volume 32
- Issue 12
Ellutia
Ellutia offers a range of gas chromatographs, GC accessories, software, and consumables. Ellutia's instruments are designed and manufactured in the UK at the company headquarters.
Company Description
Ellutia offers a range of gas chromatographs, GC accessories, software, and consumables. Ellutia's instruments are designed and manufactured in the UK at the company headquarters. The instruments are designed to be more compact, have greater energy efficiency, whilst still delivering industry standard analytical performance. Ellutia works closely with its customers and regularly produces fully customized systems tailored to their individual requirements rather than just delivering off the shelf products. It is this working relationship with customers and the flexibility to adapt that sets Ellutia apart from other GC manufacturers.
Chief Chromatographic Technique Supported
- Gas chromatography
Markets Served
- Ellutia's products can be found in a wide range of industries, including
- Brewing and malting
- Food testing
- Packaging testing
- Permeation testing
- Education
- Forensic laboratories
- Agro-chemical
- Cosmetics
- Toy production
- High purity gas
- Natural gas
- Environmental testing
Major Products/Services
- 200 Series GC: A compact and versatile single channel gas chromatograph
- 300 Series GC: A high-speed GC using resistively heated columns for ultra fast analysis cycle times
- High Purity Gas Analyzer: A rack-mounted GC for detecting impurities in gas to extremely low levels
- 800 Series TEA: Nitro, nitroso, and nitrogen detector that can be interfaced with almost any GC
- Ellution Chromatography Data Station: Software for collecting and processing data from a GC
- 7000 Flowmeter: A compact handheld flowmeter for accurately setting flows on a GC
Facilities
Ellutia's headquarters are located just outside Cambridge in the UK. This facility hosts the main research and development labs and is where all of the instruments are manufactured and tested. Outside of the UK, Ellutia also has an office in Germany and has recently opened a new dedicated sales and service organization in the US.
Ellutia
12-16 Sedgeway Business Park
Witchford
Cambridgeshire CB62HY UK
TELEPHONE
+44 1353 669916
FAX
+44 1353 669917
E-MAIL
WEB SITE
NUMBER OF EMPLOYEES
17
YEAR FOUNDED
1994
Articles in this issue
almost 12 years ago
MicroSolv Technologyalmost 12 years ago
Milestone, Inc.almost 12 years ago
Pickering Laboratoriesalmost 12 years ago
Shimadzu Scientificalmost 12 years ago
Restek Corporationalmost 12 years ago
Shodex/Showa Denko America, Inc.almost 12 years ago
SiliCycle® Inc.almost 12 years ago
AccuStandard, Inc.almost 12 years ago
CHROMacademyalmost 12 years ago
Avantor Performance Materials, Inc.Related to this article








