Discarded silicone explants, a waste material from the cosmetic surgery industry, could be a new source of sample material for studying POP accumulation in humans.
Scientists from the Norsk Instituutt for Vannforsking (Norwegian Institute for Water Research), Oslo, Norway, have proposed the analysis of silicone explants for the monitoring of persistent organic pollutants (POPs) in humans.1 The team suggest the formation of repositories for discarded silicone implants from the cosmetic surgery industry.
So, where did this idea come from? Lead author Ian J. Allan told The Column that his team has been developing passive sampling methods using silicone to measure environmental POPs for over 10 years. In a recent trial study, the team used a silicone tag in a living fish to measure the contaminants in the river.2 Analysis of the tag showed that levels of POPs were comparable to the levels in the river water, therefore providing proof of concept. Allan said: “Directly comparing concentrations in biota (in units of ng per gram lipids) with concentrations in abiotic compartments, for example in water, (pg/ng per litre) is difficult. The use of the same polymer for sampling different environmental compartments allows the comparison ofthe activity or fugacity of chemicals in these compartments more simply.”
Currently, human biomonitoring of POPs is generally performed using blood, milk, and adipose tissues — the World Health Organization (WHO) and Stockholm Convention are currently working together to survey global human exposure. These samples are difficult and expensive to obtain, whereas explanted silicone from humans is readily available. The paper quotes that an estimated 5–10 million women worldwide are implanted with silicone breast protheses, with300,000 breast augmentations performed in the USA in 2010 alone. As implants have a life-span of 10–15 years, they have to be explanted and are thendisposed of.
Allan said: “In vitro tissue exposure with passive samplingdevices and in vivo methods in clinical settings (for example, with solid-phase microextraction fibres) have received increased attention in recent years and following discussions with my colleagues we realized that it may be possible to use explanted silicone prostheses as passive sampling devices for human biomonitoring.”
With the co-operation and help of a plastic surgeon based in Oslo, Norway, 33 explanted protheses were collected from 22 female clinics undergoing surgery at a clinic in Norway. Acetone was used to extract whole samples — according to Allan, acetone was selected because of the limited effectit has on the swelling of the silicone during extraction compared to nonpolar pentane or hexane. Gas chromatography coupled to mass spectrometry (GC–MS) was subsequently performed to detect organochlorides, polychlorinated biphenyls, and polybrominated diphenyl ethers.
The samples required concentrated sulphuric acid clean-up before GC–MS analysis for acid-resistant chlorinated and brominated substances, limiting the number of compounds that could be detected and investigated. Allan told The Column that the team are now currently working on sample clean-up methods that eliminate this step, and therefore increase the number of chemicals that can be sampled and quantified. The advantage of the method is that samples can be taken from different people but still be directly compared. Allan told The Column: “Ultimately we would like to combine this sampling with non-targeted screening analytical methods.”
The team will be working on developing the study to determine the application of the method to a wider range of silicone samples produced by different manufacturers, in addition to optimizing the method to reduce the level of solvents used and to increase the number of contaminants detectable. - B.D.
References
1. I.J. Allan et al. Environment International59, 462– 468 (2013).
2. I.J. Allan et al. Environ. Sci. Technol. DOI: 10.1021/ es401810r (2013)
Measuring Procyanidin Concentration in Wines Using UHPLC
January 24th 2025Researchers from the University of Bordeaux (Villenave d'Ornon, France) report the development and validation of a rapid and quantitative analytical method measuring crown procyanidin concentration in red and white wines using ultra-high performance liquid chromatography (UHPLC) coupled with a ultra-high performance liquid chromatography (Q-TOF) mass spectrometer.
The Next Frontier for Mass Spectrometry: Maximizing Ion Utilization
January 20th 2025In this podcast, Daniel DeBord, CTO of MOBILion Systems, describes a new high resolution mass spectrometry approach that promises to increase speed and sensitivity in omics applications. MOBILion recently introduced the PAMAF mode of operation, which stands for parallel accumulation with mobility aligned fragmentation. It substantially increases the fraction of ions used for mass spectrometry analysis by replacing the functionality of the quadrupole with high resolution ion mobility. Listen to learn more about this exciting new development.
The Complexity of Oligonucleotide Separations
January 9th 2025Peter Pellegrinelli, Applications Specialist at Advanced Materials Technology (AMT) explains the complexity of oligonucleotide separations due to the unique chemical properties of these molecules. Issues such as varying length, sequence complexity, and hydrophilic-hydrophobic characteristics make efficient separations difficult. Separation scientists are addressing these challenges by modifying mobile phase compositions, using varying ion-pairing reagents, and exploring alternative separation modes like HILIC and ion-exchange chromatography. Due to these complexities, AMT has introduced the HALO® OLIGO column, which offers high-resolution, fast separations through its innovative Fused-Core® technology and high pH stability. Alongside explaining the new column, Peter looks to the future of these separations and what is next to come.
Testing Solutions for Metals and PFAS in Water
January 22nd 2025When it comes to water analysis, it can be challenging for labs to keep up with ever-changing testing regulations while also executing time-efficient, accurate, and risk-mitigating workflows. To ensure the safety of our water, there are a host of national and international regulators such as the US Environmental Protection Agency (EPA), World Health Organization (WHO), and the European Union (EU) that demand stringent testing methods for drinking water and wastewater. Those methods often call for fast implementation and lengthy processes, as well as high sensitivity and reliable instrumentation. This paper explains how your ICP-MS, ICP-OES, and LC-MS-MS workflows can be optimized for compliance with the latest requirements for water testing set by regulations like US EPA methods 200.8, 6010, 6020, and 537.1, along with ISO 17294-2. It will discuss the challenges faced by regulatory labs to meet requirements and present field-proven tips and tricks for simplified implementation and maximized uptime.