Silvia Marten
Articles by Silvia Marten


Knauer Application Note

Carbonyl compounds, in particular aldehydes, are reactive volatile substances. They are of concern to the public, because they are emitted as air pollutants by a large range of industrial processes and other combustion sources.


Catecholamines are important markers for the diagnosis and management of tumour diseases of the sympathoadrenal system. The major catecholamines are dopamine, norepinephrine and epinephrine. Urine tests have shown to be applicable to measure the level of catecholamines in the human body. Various separation methods have been used for the clean-up of catecholamines in biological fluids: solvent extraction, adsorption on alumina, ion-exchange and solid-phase extraction of a diphenylboronic acid-catecholamine complex. From the point of simplicity, reproducibility and automation the last method is the most suitable and can be realized by on-line SPE–LC. Diphenylborate forms a negatively charged complex with the diol groups of catecholamines. These complexes which are strongly retained on a polystyrene-divinylbenzene cartridge in alkaline medium (pH 8.5) can be eluted in a second step from the SPE unit directly onto the HPLC column. The separation of catecholamines is performed in isocratic mode by..

Polyaromatic hydrocarbons (PAH) are particularly relevant in the analysis of environmental pollution because of their ubiquity, toxicity and persistence. Consequently, the PAHs have become the most intensively studied pollutants in environmental analysis.

Paracetamol is a major ingredient in numerous medications due to its analgesic and antipyretic properties. During its synthesis (Figure 1), a total of ten process-related impurities are observed. Several HPLC applications have been developed for the monitoring of these impurities (1, 2), including the European Pharmacopoeia which has adopted an isocratic HPLC method using a silica-based C8 column with 5 μm particle size, requiring a run time of 45 min (3). By using a gradient method and standard HPLC instrumentation, the analysis can be reduced to 7 min (4).

In gradient mode, the quality of the analysis will be influenced by the performance of the proportioning and mixing of the eluents at any time during a given chromatogram.
Latest Updated Articles
Determination and Quantification of Primary Aromatic Amine in Printer InkPublished: September 1st 2012 | Updated:
Rapid Determination of DNPH Derivatized Carbonyl Compounds by UHPLCPublished: July 2nd 2010 | Updated:
Rapid Determination of DNPH Derivatized Carbonyl Compounds by UHPLCPublished: June 1st 2010 | Updated:
On-line SPE-LC of Catecholamines in Urine with Fluorescence DetectionPublished: December 2nd 2009 | Updated:
On-line SPE-LC of Catecholamines in Urine with Fluorescence DetectionPublished: September 1st 2010 | Updated:
High Speed Separation of More Than 16 Polycyclic Aromatic HydrocarbonsPublished: July 2nd 2009 | Updated: