
GC–MS Reveals Diego Rivera’s Wax-Free Encaustic
Key Takeaways
- GC–MS fingerprinting matched mural binders to Mexican copal and elemi resins, contradicting long-standing expectations of a beeswax-dominant encaustic medium.
- Absence of beeswax in all microsamples suggests Rivera used copal as the primary binder, potentially diluted with spike/lavender oil and/or petroleum.
Gas chromatography–mass spectrometry (GC–MS) analysis shows Diego Rivera’s first mural used copal resin, not wax.
Diego Rivera (1886–1957) painted his first mural, La Creación (Creation), using encaustic, an ancient Greek method of painting with melted beeswax and other natural resins. Rivera claimed he had given the technique a Mexican twist by adding copal, a resin that comes from the copal tree.
Researchers from the National Autonomous University of Mexico and Mexico’s National Science Laboratory for Research and Conservation of Cultural Heritage set out to find out exactly what Rivera’s paint was made of. They studied tiny samples taken from Creation, along with test panels they made themselves using Rivera’s own recipe. To analyze them, they used a range of laboratory tools, including gas chromatography–mass spectrometry (GC–MS). Their findings, published in the journal ACS Omega,¹ offer a new look at the ingredients behind Rivera’s paint.
What Is Copal?
Rivera painted his first mural, Creation between 1922 and 1923 in the amphitheater of the National Preparatory School in Mexico City, a building now known as the Antiguo Colegio de San Ildefonso. Both at the time and many years later, Rivera said he had used encaustic, a wax-based painting method, and had added copal resin to create a distinctly Mexican version of it.2,3
The word “copal” comes from copalli, a term in Nahuatl, the Indigenous language of central Mexico. It refers to the fresh sap that oozes from certain trees, mostly of the Bursera family. This sap hardens into a fragrant resin that dissolves easily and melts at low heat. People in Mexico have been harvesting and using it since long before the Spanish arrived, and to this day it is commonly burned as incense in rituals.4
The name has caused some confusion, though. “Copal” can mean either the freshly gathered resin or a fossilized form of it. In Europe during the 1700s and 1800s, the word was also used for other fossilized resins that were hard and difficult to dissolve, which is why some painting manuals of the period, such as one by Vibert, advised artists against using it. The soft, fresh copal used in Mexico is a very different material.5
What Did the Researchers Find in Rivera’s Paint?
The researchers first analyzed pure samples of the main ingredients (beeswax, Mexican copal resin, and elemi resin, another tree resin) to find each one’s chemical “fingerprint,” the telltale molecules that reveal its presence. When they compared these fingerprints with the samples from the mural, they found clear signs of both copal and elemi resins. Surprisingly, though, they found no trace of beeswax in any of the mural samples.
Every sample from the mural also contained a chemical called ethyl phthalate, which most likely came either from pollution in the surrounding environment or from protective treatments applied during past restoration work. Finally, the study looked at zinc lactate, a compound that forms as the paint breaks down over time.1
“The results,” write the authors of the paper,1 “suggest that the encaustic medium prepared by Rivera contained mainly copal resin, probably diluted with spike/lavender oil, and/or petroleum.”
Several other artists of the time who followed Rivera’s encaustic method, such as José Sabogal, Carlos Orozco Romero, and Fermín Revueltas, used recipes that combined beeswax with copal. The researchers have tested samples from some of these murals and did find beeswax in them, though that work is still ongoing and will be published later.1
It was a surprise, therefore, that Rivera’s mural contained no wax at all. Still, copal has long been used on its own as a paint binder, and it works quite well for that purpose. And even without wax, the mural can still be called encaustic, because the paint was fused into place with heat. The word “encaustic” actually refers to this heating process, not to any particular ingredient, and there has never been one fixed recipe for it.1
Read More on Similar Topics
References
- Aguilar-Rodríguez, P.; Landa-Huerta, J.; Santiago-Jiménez, A. et al. An Encaustic Without Wax: Microanalytical Binder Characterization of Diego Rivera's First Mural, Experimental Reproduction, and Identification of Degradation Products. ACS Omega. 2026, 11 (29), 43265-43276. DOI:
10.1021/acsomega.6c00983 - del Sena, J. Notas Artísticas: Diego Rivera En El Anfiteatro de La Preparatoria; El Universal Ilustrado; 1922.
- Rivera, D.; O’Gorman, J. Sobre La Encáustica y El Fresco; El Colegio Nacional; 1993.
- Montúfar López, A. Copal de Bursera Bipinnata. Una Resina Mesoamericana de Uso Ritual. Revista Trace 2016, 70, 45–77. DOI:
10.22134/trace.70.2016.39 - Vibert, J. G. La Science de La Peinture; Paul Ollendorff; 1891
Related to this article









