Gerstel, Inc.
Company Description
Gerstel develops and produces automated sample preparation and sample introduction systems for GC, GC–MS, LC, and LC–MS. Gerstel technology enhances productivity and significantly improves detection limits. Gerstel is the leading Agilent Technologies Premier Solutions Partner, providing solutions or complete systems with integrated software control. Gerstel instrumentation is also compatible with all other manufacturers' systems.
Chief Chromatographic Techniques Supported
- Autosamplers for GC, GC–MS, LC, and LC–MS
- Automated sample preparation for GC–MS and LC–MS
- Disposable pipette extraction (DPX)
- Automated solid phase extraction (SPE)
- Dynamic headspace and thermal desorption
- Headspace and solid phase microextraction (SPME)
- Twister® Stir Bar Sorptive Extraction (SBSE)
- PTV and large-volume injection
- Automated Liner Exchange (ALEX)
- Multicolumn/multidimensional GC systems
- Olfactory detection and preparative fraction collection
- Pyrolysis
Markets Served
- Foods, beverages, flavors, and fragrances
- Personal care and cosmetics
- Forensics
- Clinical research
- Microelectronics and semiconductors
- Polymers and packaging - leachables and extractables
- Environmental and industrial hygiene
- Pharmaceuticals
Major Products/Service0073
MAESTRO Software: Operates Gerstel modules and systems independently or available as integrated solutions with Agilent ChemStation/MassHunter, LECO ChromaTOF, AB Sciex Analyst®, Thermo Scientific Xcalibur, and others. One method and sequence table run the complete system including GC–MS or LC–MS.
MultiPurpose Sampler MPS: GC, GC–MS, LC, and LC–MS autosampler and sample preparation robot. Performs the sample preparation techniques listed below and more.
Automated DPX: Dispersive SPE technique for fast, efficient extraction and concentration of analytes.
Automated SPE: Independent of LC–MS or GC–MS or combined with sample introduction. Based on standard cartridges.
Dynamic Headspace (DHS): Concentrates VOCs from liquids or solids. Ultra-low detection limits.
Thermal Desorption System (TDS): Ultra-low detection limits for VOCs and SVOCs up to n-C40.
Thermal Desorption Unit (TDU): Highly flexible, automated analysis of up to 196 samples. Performs thermal desorption/extraction and pyrolysis.
Twister® Stir Bar Sorptive Extraction (SBSE): Ultra trace-level determination of organic compounds in liquid matrices. Up to 1000 times more sensitive than SPME.
Cooled Injection System (CIS): Universal PTV inlet for optimized GC performance. High temperature version up to 650 °C, cryostatic cooling.
Automated Liner EXchange (ALEX): For samples with a heavy matrix load.
Automated Centrifugation, Solvent Evaporation, Weighing, Filtration, Vortexing, and Bar Code Reading
Multidimensional GC with Column Switching: Complex separations using two or more columns.
Olfactory Detection Port (ODP): For GC or GC–MS; complete with voice recognition, intensity indication, and peak annotation.
Preparative Fraction Collector (PFC): For GC or GC–MS using up to six traps.
Facilities
Full applications support laboratory at US headquarters near Baltimore, Maryland, and a partner applications laboratory in Chicago, Illinois. Our applications team enables Gerstel to assist customers in applying GC and LC analysis techniques to the solution of real-world challenges.
Gerstel, Inc.
701 Digital Drive, Suite J
Linthicum, MD 21090
TELEPHONE
(800) 413-8160
FAX
(410) 247-5887
E-MAIL
WEB SITE
YEAR FOUNDED
1967
Articles in this issue
almost 12 years ago
MicroSolv Technologyalmost 12 years ago
Milestone, Inc.almost 12 years ago
Pickering Laboratoriesalmost 12 years ago
Shimadzu Scientificalmost 12 years ago
Restek Corporationalmost 12 years ago
Shodex/Showa Denko America, Inc.almost 12 years ago
SiliCycle® Inc.almost 12 years ago
AccuStandard, Inc.almost 12 years ago
CHROMacademyalmost 12 years ago
Avantor Performance Materials, Inc.Related to this article