At HPLC 2023, John Langley, a professor at the University of Southampton in Southampton, UK, presented a talk titled “(R)evolution of Hyphenations, Through Open-Access RP-HPLC–MS, Open-Access UHPSFC–MS and 2D -LC–IMS-MS in Academia”. He spoke with LCGC on the importance of open-access hyphenation, and how to implement it in your research.
Q. What is open-access hyphenation?
A: It’s where we bring together the need of the chemist or the user with the analyst. We have the hyphenation, that is, the chromatography that deals with separations of mixtures and the mass spectrometer for the determination of the answer, and then tuning the solution to the question in hand. That means we might want a reversed -phase hyphenation technique, or we might want gas phase chromatography, or we might need supercritical fluid chromatography (SFC) as the solution. It’s all about the chemistry of the user samples.
Q. Why is open-access hyphenation important in your laboratory?
A: Our lab wouldn’t run without open‑access hyphenation. To get through the number of samples, it’s just not feasible to do that with one person operating an instrument, or even 20 or 30 people operating the instrument as a power user. The open‑access approach means that users log samples on remotely. They can then come into the lab, scan the barcode, and put the sample into the autosampler. The instrumentation then switches on, acquires and processes the data, returning it in typically 5 min, and it just does that all day long. Without that solution, we couldn’t get through the number of samples, people couldn’t reaction monitor, we just couldn’t work. For me it’s a critical piece of technology. I’m surprised that more people don’t use it.
Q. What are the benefits of open-access reversed-phase ultrahigh-pressure liquid chromatography–mass spectrometry (RP-UHPLC–MS) and open-access ultrahigh-pressure supercritical fluid chromatography (UHPSFC)–MS (1)?
A: The move to sub-2-µm particle size has allowed us to work with chromatography in a much faster timescale, meaning we’ve got an increased peak capacity. By using reversed-phase or SFC we can look at different types of molecules with different solutions, all benefitting from sub-2-µm particle size, which means we can do faster chromatography with better resolution, so we can work with more complex systems. We need the different types of chromatography to address different classes of chemicals. We have some materials that just are not compatible with reversed phase, so they go to an SFC system. We have some materials that just do not retain using reversed-phase C18 chromatography solutions that again require SFC. It’s all about having the right tool for the right question.
Q. What are the benefits of two-dimensional (2D)-LC–ion mobility separation (IMS)-MS?
A: When thinking about the move to 2D and why we want to use 2D chromatography, we need the increased peak capacity to deal with samples that we cannot separate with one-dimensional (1D) chromatography. This is not an open-access solution however; it is a power user or multiuser solution, but it’s not on the high-throughput mode of an open-access model. We need this because we have challenges facing us to understand complex materials at the molecular level in the petrochemical world and the pharmaceutical world, and we need enhanced chromatography solutions to help us work in those spaces. The new instrumentation and the 2D approaches allow us to achieve better levels of quantitation and detection, which are going to be critical when we start looking at low levels of polyfluorinated contaminants, for example.
Q. Are you planning to evolve open-access hyphenation further?
A: The evolution of open-access solutions must keep going. We’ve evolved in the 28 years we’ve been working in this space, and we’re always looking for ways where we can change. We’ve spoken recently about how sub-2-µm particles have changed the world. We’re now in the stages of implementing an open-access non-chromatography solution using the small benchtop atmospheric solids analysis probe-mass spectrometry (ASAP-MS) system that Waters has within our open access suite, so that users can come to the lab and get their data quickly. We’ll continue to look at the right solution and change what we do open-access-wise. If we stand still, we go backwards, so we’ve always got to look forwards.
Q. Do you have advice for analysts who want to implement open-access hyphenation?
A: The first thing I would do if I was implementing open-access hyphenation now is talk to the people that have done it, talk to the guys in industry, talk to people like us because we’ve learned a lot and we know what doesn’t work. Education is a huge part of it. Once you train your user base and get them into the right mindset, a lot of the problems go away. If you’re in an environment similar to ours where we have different solutions, then we educate the users about the right solution, and we use the idea that the molecule is encoded to the correct chromatography, or the correct ionization technique, or both.
(1) Langley, G. J. (R)Evolution of Hyphenations, Through Open Access RP-HPLC–MS, Open Access UHPSFC–MS and 2D-LC–IMS-MS in Academia. Presented at: HPLC 2023. June 18–22, 2023. Düsseldorf, Germany. KN37.
TD-GC–MS and IDMS Sample Prep for CRM to Quantify Decabromodiphenyl Ether in Polystyrene Matrix
April 26th 2024At issue in this study was the certified value of decabromodiphenyl ether (BDE 209) in a polystyrene matrix CRM relative to its regulated value in the EU Restriction of Hazardous Substances Directive.
LC–MS/MS-Based System Used to Profile Ceramide Reactions to Diseases
April 26th 2024Scientists from the University of Córdoba in Córdoba, Spain recently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) to comprehensively profile human ceramides to determine their reactions to diseases.
High-Throughput 4D TIMS Method Accelerates Lipidomics Analysis
April 25th 2024Ultrahigh-pressure liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) had been previously proposed for untargeted lipidomics analysis, but this updated approach was reported by the authors to reduce run time to 4 min.