The Application Notebook-06-01-2010

i4-676269-1408632643458.jpg

The Application Notebook

With many "blockbuster" drugs losing patent protection, there has been mounting pressure across the pharmaceutical industry to shorten the time to bring new chemical entities (NCEs) to market and reduce the overall cost. This requires concerted productivity improvement in many aspects of drug discovery and development by continuously adopting new enabling technologies.

i4-676277-1408632624323.jpg

The Application Notebook

In pain management analysis, urine is often used as it is a copiously available bodily fluid that can be collected easily and used for analysis. Urine, however, can cause difficulties in analysis due to the variances in the endogenous nature of the urine matrix, which can impact the chromatographic separation and quantitation.

i3-676270-1408632640329.gif

The Application Notebook

The U.S. EPA Office of Groundwater and Drinking Water released Method 524.3, "Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry, Version 1.0," in the Federal Register on August 3rd, 2009 (1, 2). This new method contains an updated list of 76 VOCs that includes fuel oxygenates and two emerging contaminants of interest.

i2-676291-1408632582791.gif

The Application Notebook

Explosive compounds are widely used in warfare, mining industries, terrorist attacks, and civil constructions. Explosive contaminated soils are mostly found on firing points, impact areas, and training ranges. The explosive contaminates in soil are possible sources for surface and ground water contaminations, posing environmental and public health risks due to the compounds' toxicity, carcinogenicity, and mutagenicity.

i1-676283-1408632608920.jpg

The Application Notebook

Hamilton Company is best known for manufacturing precision fluid measuring products, including syringes for HPLC and GC. For the last 30 years Hamilton Company has manufactured HPLC resins and columns while developing separations for customers. Two of the separations are highlighted below.

i3-676284-1408632607264.gif

The Application Notebook

Grapefruit juice was analyzed by gradient UHPLC for naringin - a flavanoid that gives it its bitter taste. A ZORBAX Rapid Resolution HD (RRHD) StableBond-C18 2.1 x 150 mm, 1.8 µm column resolved over 60 peaks including naringin in 7 min, and was re-equilibrated in just 3 min by operating at a high flow rate (0.8 mL/min).

i1-676262-1408632670265.jpg

The Application Notebook

The speed and accuracy of software-assisted identification of metabolites can be further improved by combination with rule-based metabolite prediction software.

i2-676300-1408632555363.gif

The Application Notebook

For many years, the use of guard columns has been advocated by column manufacturers and other experts to protect and extend column lifetime and performance of analytical columns from potential damage caused by the presence of chemical contaminants and microparticulates in the sample and mobile phase.

i1-676271-1408632637987.jpg

The Application Notebook

Traditionally, summer is a time when the worlds of lab research and business slow down to a large extent. If you work in academia, chances are many of your students have returned home for the summer and the teaching load has been reduce, while those of you working in private industry and research labs may see coworkers taking long-anticipated (and well-deserved) vacations.

i1-676295-1408632567020.jpg

The Application Notebook

Heparin is well-known as an anticoagulant, antithrombotic drug. Chemically, it is a linear polysaccharide that is derived from animal tissues. For some time it has been known that heparin is not a homogeneous substance; rather, it is a heterogeneous mixture of molecules ranging in molar mass from less than 5,000 to more than 30,000 Daltons.