LC and Green Chemistry Advancements in Lenvatinib Stability Testing and Environmental Responsibility
A novel lenvatinib stability-indicating method, developed through a quality by design (QbD) approach and embracing principles of green chemistry, offers a robust solution for ensuring the drug's stability under various conditions.
In the realm of pharmaceuticals, ensuring the stability of drugs is paramount. It involves scrutinizing drug behaviors under different environmental conditions. Researchers Payal Tiwari and Mital Patel of Shri Vile Parle Kelavani Mandal's Narsee Monjee Institute of Management Studies (SVKM's NMIMS) in Mumbai, Maharashtra, India, have recently contributed to this field with a report published in Chromatographia. The authors wrote about their devising of a novel method for assessing the stability of lenvatinib, which is used to treat humans with different types of cancer, in a way that is environmentally responsible (1). This method combines a quality by design (QbD) approach with the principles of green chemistry.
Lenvatinib is a crucial anti-cancer drug used in various medical treatments, and its stability under different conditions is a critical concern. The research conducted by Tiwari and Patel is framed within the framework of International Council of Harmonisation (ICH) Quality Guidelines Q1A(R2), Stability Testing of New Drug Substances and Products, and Q3, the overall category addressing Impurities, both of which designations are designed to evaluate the degradation behavior of pharmaceuticals under diverse environmental conditions.
The researchers' QbD approach encompasses screening and optimization stages. During the screening phase, they employed the Plackett–Burman design to assess primary parameters. This step was pivotal in identifying the most influential factors in the drug's stability. Following this, response surface design (RSD) was utilized to optimize these critical factors, ensuring the utmost robustness of the method.
Lenvatinib's stability was assessed under various degradation conditions, including acidic, basic, oxidative, neutral, thermal, and photolytic conditions. Achieving separation in this process was made possible with a Shimadzu C18 column, measuring 250 mm in length and 4.6 mm in diameter, with particle sizes as small as 5 µ. The mobile phase consisted of a mixture of acetonitrile and 10 mM ammonium acetate at pH 3.5, with a ratio of 39:61 (v/v) at a flow rate of 0.8 mL/min. The runtime for the analysis was 20 min, with analyte detection at 245 nm.
What makes this research especially significant is the sensitivity of lenvatinib to acid and base hydrolysis. These reactions result in the generation of five distinct degradation products. However, the optimized analytical method developed by Tiwari and Patel—which is compatible with separation by liquid chromatography coupled to mass spectrometry (LC–MS)—successfully identified these products. The method, according to the authors, showcases high sensitivity, reproducibility, specificity, and robustness.
The linearity range of the method covered a concentration of 10 to 60 mg/mL, with a coefficient of determination (R2) of 0.9993. Such high linearity is essential for accurately assessing lenvatinib’s stability over a range of concentrations.
Furthermore, this research aligns with a growing concern for environmental responsibility within the pharmaceutical industry. Tiwari and Patel calculated the greenness score of their analytical method, revealing that it is an environmentally friendly approach. In conclusion, their research showcased the QbD approach in the development of a sensitive and reliable lenvatinib stability-indicating method that not only conforms to stringent guidelines, but also embraces green chemistry principles. This method confirms that a vital medication will remain stable under various conditions while also reducing its environmental footprint.
This article was written with the help of artificial intelligence and has been edited to ensure accuracy and clarity. You can read more about our
Reference
(1) Tiwari, P.; Patel, M. Advancing Quality and Environmental Responsibility: A Stability-Indicating LC Method Development for Lenvatinib Through QbD and Green Chemistry. Chromatographia 2023, 86, 579–593. DOI: