News|Articles|November 18, 2026

LC–MS Tracks Metabolism After Joint Replacement

Author(s)John Chasse
Listen
0:00 / 0:00

Key Takeaways

  • A 7-year cohort compared 70 arthroplasty patients with 82 matched controls, using fasting LC–MS acylcarnitine quantification and adjustment for age, sex, BMI, and hypertension.
  • Longitudinal divergence was observed in 15/48 acylcarnitines; baseline group differences expanded from six measures preoperatively to 12 measures at seven years.
SHOW MORE

Liquid chromatography–mass spectrometry (LC–MS) shows fat metabolism only partly recovers after joint replacement.

Joint replacement surgery, such as a new hip or knee, is the most effective treatment for severe osteoarthritis. Earlier research has shown that people with osteoarthritis have unusual levels of acylcarnitines in their blood, compounds that play a key role in how the body burns fat for energy. But little is known about how the body’s chemistry changes in the years after joint replacement. Previous studies have only looked at patients at a single point in time and haven’t compared them with healthy people of the same age and sex.

To fill that gap, researchers at the University of Tartu and Tartu University Hospital in Estonia tracked patients’ blood chemistry before surgery and again seven years later, comparing the results with healthy people who had aged over the same period. They took blood samples after an overnight fast and measured acylcarnitine levels using liquid chromatography–mass spectrometry, a lab technique that separates a sample into its individual chemical components and identifies them. Their findings were published in the journal Osteoarthritis and Cartilage.¹

What Are Acylcarnitines, and Why Do They Matter in Osteoarthritis?

Acylcarnitines are compounds that carry fats into mitochondria, the tiny power plants inside our cells, where the fats are burned for energy.2 This makes them key players in how the body uses fat as fuel. Their levels are known to be off in people with osteoarthritis, and they have been linked to the loss of cartilage, the cushioning tissue in joints.3

So far, though, most studies have either looked at patients at a single point in time or tracked only the short-term changes right after surgery.4-6 As far as the researchers know, no one had studied how acylcarnitine levels change over many years after joint replacement or compared those changes with healthy people of the same age and sex.1

Why Study the Body’s Chemistry After Joint Replacement?

“Considering the current lack of preventative or disease-modifying treatment,” write the authors of the paper,1 “total joint arthroplasty remains the most effective intervention for end-stage osteoarthritis. A greater understanding of the systemic metabolic abnormalities associated with advanced osteoarthritis, and whether these abnormalities persist or improve following total joint arthroplasty, could provide insight into the metabolic consequences of severe osteoarthritis and its treatment. Characterizing long-term metabolic changes may also help distinguish metabolic features that are modifiable following joint replacement from those that persist despite improvements in joint pain and function.”

Does Joint Replacement Restore the Body’s Chemistry?

The study followed 70 people with severe osteoarthritis who were having joint replacement surgery (average age 62) and 82 healthy people of the same age and sex who did not have the condition. Everyone gave blood samples after an overnight fast at the start of the study and again seven years later. The researchers compared the results both between the two groups and within each person over time, and they made sure to account for factors that could skew the picture, such as age, sex, body weight, and high blood pressure.1

Of the 48 acylcarnitine measurements that met the researchers’ quality standards, 15 changed differently over time in the surgery patients than in the healthy group. At the start, the two groups differed on six measurements; by the seven-year mark, they differed on 12. Five of the original differences had disappeared, while 11 new ones had appeared.1

The clearest changes involved seven acylcarnitines. Four of the smaller ones rose about 20% to 32% more in the surgery patients than in the healthy group, while three of the larger ones also changed differently between the groups. Free carnitine, the basic form of the compound before it attaches to fats, dropped by about a quarter relative to the healthy group. Meanwhile, several medium-sized and larger acylcarnitines that had been low in the surgery patients before their operation rose back toward normal levels. Overall, the balance between acylcarnitines and free carnitine shifted about a third more in the surgery patients, though the gap between the two groups at the start had closed by the end.1

“Total joint arthroplasty was associated with partial normalization of select circulating acylcarnitines,” wrote the authors of the paper.1 “However, persistent abnormalities in hydroxy- and dicarboxy-acylcarnitines suggest ongoing alterations in lipid handling. Reduced carnitine buffering capacity and shifts toward alternative oxidation pathways further indicate incomplete restoration of systemic fatty-acid metabolism. Overall, these findings support pathway-specific metabolic remodeling rather than full metabolic normalization following total joint arthroplasty.”


References

  1. Sõber-Williams, E. K.; Kilk, K.; Kals, J. et al. Longitudinal Remodeling of Acylcarnitine Signatures Before and After Arthroplasty for Osteoarthritis: A 7-year Cohort Study. Osteoarthritis Cartilage 2026, S1063-4584 (26), 01119-2. DOI: 10.1016/j.joca.2026.10.017
  2. Xiang, F.; Zhang, Z.; Xie, J. et al. Comprehensive Review of the Expanding Roles of the Carnitine Pool in Metabolic Physiology: Beyond Fatty Acid Oxidation. J Transl Med. 2025, 23 (1), 324. DOI: 10.1186/s12967-025-06341-5
  3. Xie, Z.; Aitken, D.; Liu, M. et al. Serum Metabolomic Signatures for Knee Cartilage Volume Loss over 10 years in Community-dwelling Older Adults. Life 2022, 12(6), 869. DOI: 10.3390/life12060869
  4. Pan, X.; Cunningham, E. L.; Passmore, A. P. et al. Cerebrospinal Fluid Spermidine, Glutamine and Putrescine Predict Postoperative Delirium Following Elective Orthopaedic Surgery. Sci Rep. 2019, 9 (1), 4191. DOI: 10.1038/s41598-019-40544-3
  5. Costello, C. A.; Hu, T.; Liu, M. et al. Differential Correlation Network Analysis Identified Novel Metabolomics Signatures for Non-responders to Total Joint Replacement in Primary Osteoarthritis Patients. Metabolomics 2020, 16 (5), 61. DOI: 10.1007/s11306-020-01683-1
  6. Jung, M.; Pan, X.; Cunningham, E. L. et al. The Influence of Orthopedic Surgery on Circulating Metabolite Levels, and their Associations with the Incidence of Postoperative Delirium. Metabolites 2022, 12 (7), 616. DOI: 10.3390/metabo12070616


Related to this article

Magnetic Aerogel Extracts Pesticides for LC–MS/MS Testing
Kazhal Khazaei of K.N. Toosi University of Technology (Iran) discusses her research team’s development of a magnetic copper-based metal-organic gel aerogel that captures tiny amounts of pesticides from plant-based milks for liquid chromatography–tandem mass spectrometry (LC–MS/MS) testing with LCGC International.