News|Videos|November 27, 2026

The Role of Portable Liquid Chromatography in Seized-Drug Analysis

Color tests, handheld Raman, and portable GC–MS struggle with designer drugs and mixtures; Ira Lurie makes the case for portable liquid chromatography.

In this interview, recorded as part of LCGC International’s EAS 2026 coverage, Ira S. Lurie of the Department of Forensic Sciences at George Washington University discusses his presentation, “Field and Lab Portable LC Instrumentation for Drugs of Abuse.” In the first of three parts, he explains why rapid on-scene identification matters and where current field tests fall short.

Lurie outlines three reasons why seized-drug analysis needs rapid on-scene identification. A preliminary test on a suspected powder at an airport can establish probable cause for an arrest. Ruling out a controlled substance on the spot saves paperwork and keeps unnecessary samples out of the backlogs that forensic laboratories carry. And for intelligence, an agent who knows whether seized heroin is high or low purity can judge whether it points to a larger case.1

The tools available at remote sites each have gaps. Color tests lack specificity, because several drugs can give the same color, and for most emerging or designer drugs no color test exists. Handheld Raman and Fourier transform infrared (FT-IR) analyzers are fast, but major components can mask minor ones; Lurie gives the example of 1% fentanyl in heroin, which may go undetected. Ion mobility spectrometry produces collision cross section (CCS) data that more than one drug can share, and it has limited resolving power. Portable gas chromatography (GC) with ion trap mass spectrometry (MS) lacks molecular ion data for drug classes including substituted phenethylamines and fentanyl analogs, struggles with positional isomers, and is unsuited to thermally labile, polar, or non-volatile drugs.

Liquid chromatography (LC) addresses many of these problems.2,3 It is amenable to dilute-and-shoot, handles mixtures well, and, coupled with electrospray ionization and an ion trap MS, gives pseudomolecular ions for most drugs. Photodiode array (PDA) detection can distinguish positional isomers substituted on the benzene ring. Lurie, who has taken part in clandestine laboratory raids, adds that samples from those sites, with incomplete reactions, precursors, and finished product, can be too complex for spectroscopic techniques, and that LC with UV detection is well suited to measuring drug purity.

Lurie answered the following question:

  • What problems in current forensic practice make portable liquid chromatography worth pursuing for seized-drug analysis?

References

  1. Lurie, I. S. Field and Lab Portable LC Instrumentation for Drugs of Abuse. Presented at EAS 2026, in Plainsboro, NJ, USA. https://eas.org/wp-content/uploads/2026/08/EAS-Preliminary-Program-2026-Updatedx2-1.pdf (accessed 2026-11-20).
  2. May, M. C.; Pavone, D. C.; Lurie, I. S. The Separation and Identification of Synthetic Cathinones by Portable Low Microflow Liquid Chromatography with Dual Capillary Columns in Series and Dual Wavelength Ultraviolet Detection. J. Sep. Sci. 2020, 43 (19), 3756–3764. DOI: 10.1002/jssc.202000767
  3. Foster, S. W.; Xie, X.; Pham, M.; et al. Portable Capillary Liquid Chromatography for Pharmaceutical and Illicit Drug Analysis. J. Sep. Sci. 2020, 43 (9–10), 1623–1627. DOI: 10.1002/jssc.201901276


Related to this article