A recent study has introduced comprehensive quality control procedures for large-scale plasma proteomics analyses. The research provides valuable insights into optimizing performance, enhancing reproducibility, and ensuring quantitative accuracy in proteomics investigations.
Proteomics research has undergone a significant transformation with the integration of high-throughput liquid chromatography tandem mass spectrometry (LC–MS/MS) instruments and advanced automated sample preparation techniques. However, when it comes to scaling proteomics experiments for large sample cohorts, robust quality control (QC) procedures are crucial. In a groundbreaking study published in the Journal of the American Society for Mass Spectrometry, lead author Renã A. S. Robinson from Vanderbilt University presents an innovative approach to establishing comprehensive QC protocols for large-scale plasma proteomics analyses (1).
To address the challenges of reproducibility and quantitative accuracy in proteomics experiments involving hundreds to thousands of samples, the research team conducted a plasma proteomics study using tandem mass tag (TMTpro) 16-plex batches. Over a 10-month data acquisition period, a total of 271 pooled QC LC–MS/MS result files were collected from the analysis of a patient-derived pooled plasma sample, which represented the entire cohort population. This sample was labeled with TMTzero or TMTpro reagents, allowing for performance monitoring of the LC–MS/MS instruments and within and across sample batch normalization.
Various analytical metrics, including protein and peptide identifications, peptide spectral matches (PSMs), MS/MS spectra acquisition, average peptide abundance, and retention time of selected tracking peptides, were evaluated to establish a robust LC–MS/MS QC workflow for future cohort studies. These metrics provided valuable insights into instrumental and data analysis variability, aiding in the identification of potential performance issues and enabling real-time troubleshooting.
The study not only outlined the QC procedures specifically tailored for large-scale plasma proteomics analyses but also provided general recommendations on using selected metrics for daily QC checks. By implementing these protocols, researchers can enhance reproducibility, improve quantitative accuracy, and achieve more reliable results in their proteomics investigations.
The establishment of comprehensive QC procedures for large-scale plasma proteomics analyses marks a significant milestone in the field, paving the way for more rigorous and standardized approaches in biomarker discovery, disease research, and personalized medicine. The findings presented in this study offer valuable insights into optimizing LC–MS/MS performance and highlight the importance of robust QC protocols in proteomics research.
(1) Patterson, K. L.; Arul, A. B.; Choi, M. J; Oliver, N. C.; Whitaker, M. D.; Bodrick, A. C.; Libbuy, J. B.; Hansen, S.; Dumitrescu, L.; Gifford, K. A.; Jefferson, A. L.; Hohman, T. J.; Robinson, R. A. S.; Establishing Quality Control Procedures for Large-Scale Plasma Proteomics Analyses. J. Am. Soc. Mass Spectrom. 2023. DOI: https://doi.org/10.1021/jasms.3c00050
TD-GC–MS and IDMS Sample Prep for CRM to Quantify Decabromodiphenyl Ether in Polystyrene Matrix
April 26th 2024At issue in this study was the certified value of decabromodiphenyl ether (BDE 209) in a polystyrene matrix CRM relative to its regulated value in the EU Restriction of Hazardous Substances Directive.
LC–MS/MS-Based System Used to Profile Ceramide Reactions to Diseases
April 26th 2024Scientists from the University of Córdoba in Córdoba, Spain recently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) to comprehensively profile human ceramides to determine their reactions to diseases.
High-Throughput 4D TIMS Method Accelerates Lipidomics Analysis
April 25th 2024Ultrahigh-pressure liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) had been previously proposed for untargeted lipidomics analysis, but this updated approach was reported by the authors to reduce run time to 4 min.