David Semin

Articles by David Semin

figure 1-11473169362325.jpg

LCGC Asia Pacific

Ultrahigh-pressure liquid chromatography (UHPLC) instruments from different manufacturers and instruments with different configurations can produce significant variations in chromatographic separation. The variety in instrument configuration increases the complexity of the method development process, which now requires a more thorough evaluation of the effect of instrument variations on the method. The studies presented here determined the typical interinstrument variations in dwell volume, extracolumn dispersion, and mixing efficiency as measured by mobile-phase compositional accuracy. Additionally, the dwell volume and extracolumn dispersion were independently and systematically varied to evaluate the resulting impact on resolution for a small-molecule test mixture during gradient elution. To account for these interinstrument variations, dwell volume and wash-out volume method translation and adjustment techniques were evaluated.

figure 2.jpg

LCGC Europe

Ultrahigh-pressure liquid chromatography (UHPLC) instruments from different manufacturers and instruments with different configurations can produce significant variations in chromatographic separation. The variety in instrument configuration increases the complexity of the method development process, which now requires a more thorough evaluation of the effect of instrument variations on the method. The studies presented here determined the typical interinstrument variations in dwell volume, extracolumn dispersion, and mixing efficiency as measured by mobile-phase compositional accuracy. Additionally, the dwell volume and extracolumn dispersion were independently and systematically varied to evaluate the resulting impact on resolution for a small-molecule test mixture during gradient elution. To account for these interinstrument variations, dwell volume and wash-out volume method translation and adjustment techniques were evaluated.

Blue-Figure-5-web.jpg

LCGC North America

UHPLC instruments from different manufacturers and instruments with different configurations can produce significant variations in chromatographic separation. The variety in instrument configuration increases the complexity of the method development process, which now requires a more thorough evaluation of the effect of instrument variations on the method. The studies presented here determined the typical inter-instrument variations in dwell volume, extra-column dispersion, and mixing efficiency as measured by mobile phase compositional accuracy. Additionally, the dwell volume and extra-column dispersion were independently and systematically varied to evaluate the resulting impact on resolution for a small molecule test mixture during gradient elution. To account for these inter-instrument variations, dwell volume and wash-out volume method translation and adjustment techniques were evaluated.

LCGC Europe

This article describes the pros and cons of pSFC–MS and attempts to demonstrate its broad applicability to such fields as high-throughput analysis, purity assessment, structure characterization and purification. It concludes with a look at the potential of the technique in the future of analytical drug discovery.