
LC–MS Proteomics Maps Bowel and Pancreatic Cancers
Key Takeaways
- Combined RNA-seq and LC-MS proteomics was feasible on FFPE diagnostic biopsies, with proteomics providing nonredundant information when tissue constraints limited multi-omic coverage.
- Weak average RNA–protein correlation indicated transcript abundance poorly predicts protein levels, supporting proteome-level interrogation for actionable biology and biomarker discovery.
Liquid chromatography–mass spectrometry (LC–MS) proteomics shows spreading colorectal and pancreatic tumors differ.
Colorectal cancer and pancreatic cancer are two of the most common and deadly cancers. Scientists have studied them extensively, looking at which genes are switched on, what is happening at the molecular level, and how the immune system responds, but there’s still a lot we do not understand. Both cancers are very difficult to treat, and learning more about how they work and how they interact with the immune system is key to helping patients do better.
A Norwegian research team studied 29 tissue samples taken at diagnosis from 16 people with colorectal cancer and 11 with pancreatic cancer. The samples came both from the original tumors and from places where the cancer had spread. The researchers used two approaches: reading the genetic messages in each sample to see which genes were switched on, and using liquid chromatography–mass spectrometry (LC-MS) to measure the proteins present. For the original pancreatic tumors, there was not enough tissue to do both, so only the proteins were measured. Their findings were published in the journal Biochemistry and Biophysics Reports.¹
Why Is Chemotherapy So Hard to Deliver to Tumors?
One of the biggest obstacles to making chemotherapy work against solid tumors is that the drugs often have trouble getting into the tumor in the first place.2,3 Several things stand in the way. The drugs don’t stay in the bloodstream for long, they have a hard time slipping out of blood vessels into the tumor, and once there, they must push through a dense mesh of tough fibers and jelly-like material that surrounds the cancer cells. On top of that, other cells in and around the tumor, such as connective tissue cells and immune cells, can soak up the drugs before they reach their target.2
These problems affect all solid tumors, but they are especially severe in pancreatic cancer. Pancreatic tumors are wrapped in unusually thick, scar-like tissue and have a poor blood supply, making it particularly hard for drugs to get in.4 Adding to the challenge, cancers vary a great deal, not only from patient to patient but even within a single tumor, which makes them harder still to treat effectively.5
What Did the Tumor Samples Reveal?
After reading the genetic messages and using LC-MS to measure the proteins present, the team then used a range of statistical and computer tools to make sense of the data. They checked how well the genetic messages matched the actual proteins, grouped samples by how similar they were, looked for genes and proteins that differed between groups, identified the biological processes those differences pointed to, and estimated which types of immune cells were present in each sample.1
Across all the samples, the researchers detected about 46,500 genetic messages and nearly 7000 proteins, with around 5500 genes showing up in both sets of data. However, the genetic messages and the proteins did not line up very closely: on average, how active a gene was turned out to be only a weak predictor of how much of its protein was present.1
When the researchers compared tumors that had spread with the original tumors, they found differences in both cancers. In colorectal cancer, 5 genetic messages and 99 proteins differed between the two. In pancreatic cancer, where only proteins could be compared, 305 proteins differed. When the samples were sorted purely by how similar they were, the colorectal and pancreatic samples fell neatly into two separate groups.1
The tumors that had spread also showed distinct shifts in which biological processes were ramped up or dialed down compared with the original tumors. Finally, the researchers’ estimates of the immune cells in the samples pointed to large numbers of “resting” memory T cells, immune cells that remember past threats but were not actively fighting, and of macrophages, a type of immune cell, in an inactive, uncommitted state.1
“This exploratory study,” write the authors of the paper,1 “supports the feasibility of combined RNA sequencing and proteomic profiling from limited formalin-fixed paraffin-embedded diagnostic biopsies and highlights proteomics as an important complement to transcriptomics. These findings enhance our understanding of biological and immunological heterogeneity and require further validation in larger independent cohorts for future development of prognostic markers and novel immunotherapeutic strategies.”
Read More on Similar Topics
References
- Nordlund, V.; Haram, M.; Hofsli, E. et al. RNA Sequencing and Proteomic Analysis of Diagnostic Biopsies from Colorectal and Pancreatic Cancer. Biochem Biophys Rep. 2026, 48, 102846. DOI:
10.1016/j.bbrep.2026.102846 - Sriraman, S. K.; Aryasomayajula, B.; Torchilin, V. P. Barriers to Drug Delivery in Solid Tumors. Tissue Barriers2014, 2, e29528. DOI:
10.4161/tisb.29528 - Dewhirst, M. W.; Secomb, T. W. Transport of Drugs from Blood Vessels to Tumour Tissue. Nat. Rev. Cancer2017, 17, 738-750. DOI:
10.1038/nrc.2017.93 - Bazeed, A. Y.; Day, C. M.; Garg, S. Pancreatic Cancer: Challenges and Opportunities in Locoregional Therapies. Cancers 2022,14, 4257. DOI:
10.3390/cancers14174257 - Zhu, L.; Jiang, M.; Wang, H. et al. A Narrative Review of Tumor Heterogeneity and Challenges to Tumor Drug Therapy. Ann. Transl. Med.2021, 9, 1351. DOI:
10.21037/atm-21-1948
Related to this article








