Ep. 49: Small Particles, Big Questions: O-PTIR Applications from Micro- and Nanoplastics and Protein Misfolding to Museum Treasures (Part 1)
Welcome to “Analytically Speaking,” the podcast from LCGC International and Spectroscopy.
Here in Episode #49, podcast host Dr. Jerry Workman speaks with Dr. Mustafa Kansiz, who is currently the Director of Product Management at Photothermal Spectroscopy Corporation in Santa Barbara, California. Picking up where Episode #43 left off, they follow optical photothermal infrared (O-PTIR) spectroscopy from how it works to what it reveals, asking three deceptively simple questions about the world’s smallest particles: What is it? Where is it? And what is happening around it? This is Part 1 of a two-part conversation.
Across both parts, the conversation travels from microplastics inside intestinal cells and human colon tissue, to nanoplastics and protein misfolding, bioaerosols that defeat Raman because of fluorescence, the chemistry of inhaled medicines, single bacterial cells facing antibiotics, contamination in hard-drive manufacturing, ancient microfossils, and corroding sixteenth-century glass and brass. Along the way, they discuss why precisely locating a particle is part of the measurement, and how to keep the claims tied to what the experiments actually show.
About the Guest
Dr. Mustafa Kansiz is the Director of Product Management at Photothermal Spectroscopy Corporation (PSC) in Santa Barbara, California, the company that commercialized O-PTIR. He works at the intersection of instrument development and applications and is a coauthor of several of the studies discussed in this episode, including the O-PTIR tutorial in APL Photonics, the Seagate contamination study, and the imaging of amyloid aggregates in neurons.
Google Scholar:
LinkedIn:
Photothermal Spectroscopy Corp.:
In this episode:
- Back for round two: Mustafa returns after Episode 43’s introduction to optical photothermal IR (O-PTIR) to talk about the most surprising applications since then, all focused on small particles.
- The small-particle challenge: We look at why conventional FT-IR and Raman struggle to say what a particle is, where it is, and what’s happening around it. A 200 nm plastic sphere weighs only about 4 femtograms, and finding each particle’s center before measuring is part of getting a good spectrum.
- Plastics meet cells: A 2026 study tracked degraded microplastics taken up by intestinal cells. It identified four polymer types and the cells’ lipid and protein response in a single measurement.
- Protein misfolding: We discuss imaging amyloid inside neurons, and what experiments with roughly 200 nm polystyrene can and can’t tell us about human disease.
- Plastics in tissue: Particles were found directly in human colon sections and in whole organisms, with their anatomical context kept. We cover the pitfalls, such as paraffin that looks like polyethylene, and what makes a tissue study trustworthy.
- Keeping perspective: We weigh the evidence across exposure, biological response, and disease, and revisit the landmark study of baby-bottle nipples releasing particles during steam disinfection, and how to explain it to parents without overstating it.
References and Further Information for O-PTIR Applications
Background: Understanding O-PTIR
These two reviews provide an accessible introduction to the technique and a recent, broad overview of its applications across the life, environmental, and materials sciences, including guidance on interpretation and reproducibility.
(1) Prater, C. B.; Kansiz, M.; Cheng, J.-X. A Tutorial on Optical Photothermal Infrared (O-PTIR) Microscopy. APL Photonics 2024, 9 (9), 091101. DOI:
(2) Ayala, A. M.; Smith, J. H.; Lei, Z.; Ault, A. P. Optical Photothermal Infrared Spectroscopy. Nat. Rev. Methods Primers 2026, 6 (1), 71. DOI:
When Plastics Meet Biology
Studies that identify micro- and nanoplastics while keeping the surrounding cells and tissue intact, linking particle chemistry to biological context and response.
(3) Sofield, C. E.; Attenborough, E.; Anderton, R. S.; Gorecki, A. M.; Chiu, L. S.; Anyaegbu, C. C.; Kochan, K. Label-Free Non-Destructive Spectroscopic Detection of Mixed Microplastic Uptake and Differential Effects on Intestinal Epithelial Cells. J. Hazard. Mater. 2026, 504, 141283. DOI:
(4) da Silva, I. A. N.; Paulus, A.; Skoryk, V.; Su, K.-Y.; Herranz-Trillo, F.; Klementieva, O. Polystyrene Nanoplastic Exposure Promotes Amyloid Misfolding and Metabolic Impairment at Sublethal Doses. A Subcellular Infrared Imaging Study. Environ. Sci.: Nano 2026, 13 (4), 1948–1961. DOI:
(5) Gruber, E. S.; Karl, V.; Duswald, K.; Bhamidipalli, M. S.; Schlederer, M.; Limberger, T.; Kopatz, V.; Teleky, B.; Kenner, L.; Brandstetter, M. Method for Label-Free & Non-Destructive Detection of Microplastics in Human Formalin-Fixed Paraffin-Embedded Tissue Sections. Sci. Rep. 2025, 15, 42637. DOI:
(6) Macairan, J.-R.; Saherwala, A.; Li, F.; Monteil-Rivera, F.; Tufenkji, N. Label-Free Identification and Imaging of Microplastic and Nanoplastic Biouptake Using Optical Photothermal Infrared Microspectroscopy. Environ. Sci. Technol. 2025, 59 (30), 15612–15622. DOI:
(7) HassanMazandarani, A.; Masterson, J. M.; Querido, W.; Steplewski, A.; Zhang, Y.; Huynh, C.; Garcia, M. M.; Fertala, A.; Pleshko, N. Optical Photothermal Infrared Spectroscopic Assessment of Microplastics in Tissue Models and Non-Digested Human Tissue Sections. Analyst 2026, 151 (6), 1774–1785. DOI:
(8) Su, Y.; Hu, X.; Tang, H.; Lu, K.; Li, H.; Liu, S.; Xing, B.; Ji, R. Steam Disinfection Releases Micro(nano)plastics from Silicone-Rubber Baby Teats as Examined by Optical Photothermal Infrared Microspectroscopy. Nat. Nanotechnol. 2022, 17 (1), 76–85. DOI:
Particles in the Air and in Our Medicines
From fluorescent bioaerosols that Raman cannot measure to the chemistry of inhaled and nasal drug particles.
(9) Olson, N. E.; Xiao, Y.; Lei, Z.; Ault, A. P. Simultaneous Optical Photothermal Infrared (O-PTIR) and Raman Spectroscopy of Submicrometer Atmospheric Particles. Anal. Chem. 2020, 92 (14), 9932–9939. DOI:
(10) Shi, J. H.; Poworoznek, C. J.; Parham, R. L.; Kolozsvari, K. R.; Olson, N. E.; Xiao, Y.; Lei, Z.; Birbeck, J. A.; Jacquemin, S. J.; Westrick, J. A.; Ault, A. P. Bioaerosol Characterization with Vibrational Spectroscopy: Overcoming Fluorescence with Photothermal Infrared (PTIR) Spectroscopy. J. Phys. Chem. A 2025, 129 (5), 1429–1440. DOI:
(11) Khanal, D.; Kim, J.; Zhang, J.; Ke, W.-R.; Banaszak Holl, M. M.; Chan, H.-K. Optical Photothermal Infrared Spectroscopy for Nanochemical Analysis of Pharmaceutical Dry Powder Aerosols. Int. J. Pharm. 2023, 632, 122563. DOI:
(12) Khanal, D.; Cao, Y.; Tai, W.; Chan, H.-K. O-PTIR Spectroscopy for Characterizing Active Pharmaceutical Ingredient Specific Particle Size Distributions of Nasal Spray Suspension Products. Int. J. Pharm. 2024, 664, 124653. DOI:
Cells, Bacteria, and Vesicles
Biological particles analyzed one at a time, from protein structure inside neurons to antibiotic response in single bacterial cells.
(13) Klementieva, O.; Sandt, C.; Martinsson, I.; Kansiz, M.; Gouras, G. K.; Borondics, F. Super-Resolution Infrared Imaging of Polymorphic Amyloid Aggregates Directly in Neurons. Adv. Sci. 2020, 7 (6), 1903004. DOI:
(14) Shams, S.; Lima, C.; Xu, Y.; Ahmed, S.; Goodacre, R.; Muhamadali, H. Optical Photothermal Infrared Spectroscopy: A Novel Solution for Rapid Identification of Antimicrobial Resistance at the Single-Cell Level via Deuterium Isotope Labeling. Front. Microbiol. 2023, 14, 1077106. DOI:
(15) Clarke, E. J.; Lima, C.; Anderson, J. R.; Castanheira, C.; Beckett, A.; James, V.; Hyett, J.; Goodacre, R.; Peffers, M. J. Optical Photothermal Infrared Spectroscopy Can Differentiate Equine Osteoarthritic Plasma Extracellular Vesicles from Healthy Controls. Anal. Methods 2022, 14 (37), 3661–3670. DOI:
(16) Shuster, S. O.; Curtis, A. E.; Davis, C. M. Optical Photothermal Infrared Imaging Using Metabolic Probes in Biological Systems. Anal. Chem. 2025, 97 (15), 8202–8212. DOI:
Factories, Fossils, and Forgotten Treasures
Industrial contamination, polymer interfaces, ancient organic matter, and cultural heritage objects.
(17) Kansiz, M.; Prater, C.; Dillon, E.; Lo, M.; Anderson, J.; Marcott, C.; Demissie, A.; Chen, Y.; Kunkel, G. Optical Photothermal Infrared Microspectroscopy with Simultaneous Raman – A New Non-Contact Failure Analysis Technique for Identification of <10 μm Organic Contamination in the Hard Drive and Other Electronics Industries. Microsc. Today 2020, 28 (3), 26–36. DOI:
(18) Marcott, C.; Kansiz, M.; Dillon, E.; Cook, D.; Mang, M. N.; Noda, I. Two-Dimensional Correlation Analysis of Highly Spatially Resolved Simultaneous IR and Raman Spectral Imaging of Bioplastics Composite Using Optical Photothermal Infrared and Raman Spectroscopy. J. Mol. Struct. 2020, 1210, 128045. DOI:
(19) Jubb, A. M.; Stokes, M. R.; McAleer, R. J.; Hackley, P. C.; Dillon, E.; Qu, J. Mapping Ancient Sedimentary Organic Matter Molecular Structure at Nanoscales Using Optical Photothermal Infrared Spectroscopy. Org. Geochem. 2023, 177, 104569. DOI:
(20) Marchetti, A.; Beltran, V.; Nuyts, G.; Borondics, F.; De Meyer, S.; Van Bos, M.; Jaroszewicz, J.; Otten, E.; Debulpaep, M.; De Wael, K. Novel Optical Photothermal Infrared (O-PTIR) Spectroscopy for the Noninvasive Characterization of Heritage Glass-Metal Objects. Sci. Adv. 2022, 8 (9), eabl6769. DOI:
(21) Beltran, V.; Marchetti, A.; Nuyts, G.; Leeuwestein, M.; Sandt, C.; Borondics, F.; De Wael, K. Nanoscale Analysis of Historical Paintings by Means of O-PTIR Spectroscopy: The Identification of the Organic Particles in L′Arlésienne (Portrait of Madame Ginoux) by Van Gogh. Angew. Chem. Int. Ed. 2021, 60 (42), 22753–22760. DOI:
Additional Resources
(22) Kansiz, M.; Prater, C. Understanding New Tools for Microplastics and Particle Analysis (interview by A. Salazar). AZoM, January 23, 2026. Available at:
(23) Dahl, K.; Kansiz, M. O-PTIR of Biopharmaceutical Particulates; White Paper WP01; Photothermal Spectroscopy Corp., 2025. Available at:
(24) Prater, C.; Cheng, J.-X.; Kansiz, M. An Introduction to Optical Photothermal Infrared (O-PTIR) Spectroscopy. Spectroscopy Online, September 22, 2025. Available at:
Missed the introduction? Listen to Analytically Speaking
More about our hosts:
Dwight Stoll, PhD:
Dwight R. Stoll is a professor of chemistry at Gustavus Adolphus College in St. Peter, Minnesota. He received his PhD from the University of Minnesota, under Professor Peter Carr, working on the development of fast, comprehensive two-dimensional liquid chromatography (2D-LC). Stoll’s current primary research focus is on the development of 2D-LC for both targeted and untargeted analyses. Active research projects in his laboratory touch on most aspects of multidimensional separation methodologies, including optimization strategies, characterization of selectivity in reversed-phase LC, instrument development, and applications in biopharmaceutical analysis. Stoll is the author or co-author of more than 100 peer-reviewed publications and six book chapters and has instructed numerous short courses in 2D-LC. In 2011 he was the recipient of LCGC’s Emerging Leader in Chromatography Award. In 2017 he received the Georges Guiochon Faculty Fellowship, and was recognized with an Agilent Technologies Thought Leader Award. He is also a member of LCGC’s editorial advisory board and is the editor of the “LC Troubleshooting” column in LCGC.
Jerome Workman, Jr., PhD:
Jerome (Jerry) J. Workman, Jr. is the Associate Editorial Director for Spectroscopy. He has held positions as CTO, executive VP, senior research fellow, director, and senior scientist at companies of all sizes, from start-ups to world-leading corporations. He has been an adjunct faculty member of four universities and advised multiple graduate students. He has more than 75 U.S. and international patent applications and 30 issued U.S. and international patents and multiple trade secrets, as well as 500+ technical publications, and 20 reference book volumes on a broad range of spectroscopy and data processing techniques. He has received multiple awards from scientific societies, and has taught annual courses in spectroscopy, chemometrics, and statistics for the AOAC, ACS, ISA, FACSS, and at several universities and corporations. He is a Fellow of the American Institute of Chemists (FAIC), the American Society for Testing and Materials (ASTM), and the Royal Society of Chemistry in the UK (FRSC, CChem, CSci). Jerry holds B.A and M.A degrees from Saint Mary's University of Minnesota, and a PhD degree from Columbia Pacific University working in near-infrared spectroscopy. He is an alumnus of both Columbia University Business School and the MIT Sloan School of Management.
About the Analytically Speaking Podcast:
Analytically Speaking, the podcast from LCGC and Spectroscopy, addresses important issues in separation science and analytical spectroscopy. Topics include new analytical techniques, methods, and approaches; the latest trends; advances in instrument and software technology; practical solutions for specific applications; recent papers in the scientific literature and their applicability; challenges and solutions for data analysis and interpretation; analytical chemistry theory and fundamentals (from advanced research to tutorials and troubleshooting); and more. Our regular hosts are Dwight Stoll, PhD, a professor of chemistry at Gustavus Adolphus College in St. Peter, Minnesota, and Jerry Workman, PhD, a spectroscopist, noted author, and currently the Associate Editorial Director for Spectroscopy. Dwight covers separation science and Jerry addresses spectroscopy related topics.
Connect with us on social media:
Subscribe to
Email us at
Related to this article