Using Chemometrics to Compare Mead Volatile Profiles

Sarah Foster found Abbaye yeast meads clustered apart in PCA and HCA, driven by furfural, ethyl octanoate, ethyl decanoate, and furan-2,5-dicarbaldehyde.

When multivariate analysis separates samples, the next questions are which compounds are responsible and whether the pattern holds up. In this EAS 2026 interview, Sarah Foster, an undergraduate researcher at William & Mary, discusses meads she and her team brewed with several yeast strains at different honey concentrations.1,2 In principal component analysis (PCA), most samples grouped by honey concentration, but meads brewed with Abbaye yeast clustered on their own. She explains how the team traced that separation to specific compounds, and why PCA and hierarchical cluster analysis (HCA) do not always group samples the same way.

Using the PCA loadings plot, the team identified compounds in the Abbaye meads that were not present in the other samples, including furan-2,5-dicarbaldehyde, ethyl decanoate, ethyl octanoate, and furfural. Peak areas confirmed these compounds were more abundant in the Abbaye meads. HCA also grouped the Abbaye meads separately from all other strains, which Foster attributes to the yeast’s different genetic composition: it likely metabolizes honey differently and produces different volatile compounds. The discussion also covers why D47 overlapped with Kveik Voss in PCA but clustered most closely with EC1118 in HCA. Foster explains that PCA reduces dimensionality to plot multivariate data in two dimensions, while HCA builds a dendrogram from a full dissimilarity matrix without reducing dimensionality, so samples that overlap in PCA can still separate in HCA. PCA groups samples by correlated variables that contribute most to overall variance, whereas HCA, which can use Euclidean or non-Euclidean distance measures, clusters on the presence and relative abundance of analytes. She sees the two methods as complementary: HCA shows the chemical relationships between sample groups, and PCA shows which variables drive the differences.

Foster answered the following questions:

  • PCA grouped the meads by honey concentration, except those brewed with Abbaye yeast. How did you find the compounds behind that, and confirm the pattern?
  • D47 overlapped with Kveik Voss in PCA but clustered with EC1118 in HCA. Why was there a difference, and how should analysts use both methods?

Watch the rest of the interview here:
The Role of GC×GC–TOF-MS in Resolving Co-Eluting Volatiles in Mead
Principal Component Analysis of Mead Fermentation Kinetics

References

  1. Foster, S. C.; Perrault Uptmor, K.; Straight, S. W. Understanding Mead Production via Comprehensive Two-Dimensional Gas Chromatography, Fermentation Kinetics, and Chemometric Analysis. Presented at EAS 2026, in Plainsboro, NJ, USA. https://eas.org/wp-content/uploads/2026/08/EAS-Preliminary-Program-2026-Updatedx2-1.pdf (accessed 2026-11-20).
  2. Foster, S. C.; Chasse, J. Volatile Organic Compound Profiling of Commercial Kombucha Using GC-TOF-MS and GC×GC-TOF-MS. LCGC International website https://www.chromatographyonline.com/view/volatile-organic-compound-profiling-of-commercial-kombucha-using-gc-tof-ms-and-gc-gc-tof-ms (accessed 2026-11-20).