HPLC Tracks Atropine in Myopia Contact Lenses
Key Takeaways
- Increasing myopia burden and progression heighten risks of vision-threatening sequelae, motivating sustained, multimodal control strategies beyond single interventions.
- Atropine base was complexed with hydroxypropyl β-cyclodextrin to enhance solubility and stability in saline formulations designed to approximate ocular conditions.
High-performance liquid chromatography (HPLC) shows atropine for myopia contact lenses stays stable for a year.
Nearsightedness, known medically as myopia, is a vision problem affecting people around the world. It carries a heavy economic cost and, in severe cases, can even lead to blindness. Current treatments include atropine eye drops, special contact lenses, glasses, and lifestyle changes, but none of these works very well on its own, so they are often used together. This inspired researchers to try combining two of these treatments in one. They developed stable atropine solutions, loaded them into contact lenses, and measured how the lenses released the medication over time. To check that the solutions stayed stable, they stored them at room temperature for a full year and tested them regularly using high-performance liquid chromatography (HPLC) toseparate samples of the solutions into their individual chemical components. Their findings were published in the journal Optometry and Vision Science.¹
Why Is Nearsightedness a Growing Concern?
Nearsightedness is a common eye condition that affects many people around the world.2-6 It is especially widespread in industrialized countries, where nearly half the population has it.6,7 The condition develops largely because the eyeball grows too long from front to back. If it is not kept in check, it can get worse over time and raise the risk of serious eye problems, including cataracts, a detached retina, damage to the central part of the retina, and glaucoma.6,8 Today, atropine eye drops, contact lenses, glasses, and spending more time outdoors can all help slow nearsightedness from getting worse, but none of these works fully on its own.6,9,10
Can Contact Lenses Deliver Atropine Safely and Effectively?
The researchers first converted atropine into a slightly different chemical form and paired it with a ring-shaped sugar molecule that wraps around the drug to help keep it dissolved and stable. They mixed this into a salt solution similar to the body’s natural fluids, preparing two versions: one slightly acidic and one closer to neutral, like tears. They then soaked two types of soft contact lenses in the solutions for 24 hours, measured how much of the drug the lenses absorbed and later released, and ran a standard safety test to check whether anything coming out of the lenses could harm cells.1
After a year in storage, the slightly acidic solution had held onto about 97% of its atropine, while the more neutral one kept about 80%. When soaked in the slightly acidic solution, one lens type absorbed nearly twice as much atropine as the other. The two lenses also released the drug differently: the first let out all its atropine within four hours, while the second released a little more than half within two hours. Neither lens released anything harmful to cells.1
“These findings,” write the authors of the paper,1 “support the stability and safety of atropine base formulations for potential ocular drug delivery.”
Read More on Similar Topics
References
- Aziz, M. A.; Maulvi, F.; Kuppusamy, R. et al. Delivery of Atropine Complexed with Hydroxypropyl Beta-cyclodextrin Via a Contact Lens. Optom Vis Sci. 2026, 103 (11), e70115. DOI:
10.1002/ovs2.70115 - Sankaridurg, P.; Tahhan, N.; Kandel, H. et al. IMI Impact of Myopia. Invest Ophthalmol Vis Sci. 2021, 62, 2. DOI:
10.1167/iovs.62.5.2 - Holden, B. A.; Fricke, T. R.; Wilson, D. A. et al. Global Prevalence of Myopia and High Myopia and Temporal Trends From 2000 Through 2050. Ophthalmology 2016, 123, 1036–1042. DOI:
10.1016/j.ophtha.2016.01.006 - Cai, X.-B.; Shen, S.-R.; Chen, D.-F. et al. An Overview of Myopia Genetics. Exp Eye Res. 2019, 188, 107778. DOI:
10.1016/j.exer.2019.107778 - Biswas, S.; El Kareh, A.; Qureshi, M. et al. The Influence of the Environment and Lifestyle on Myopia. J Physiol Anthropol. 2024, 43, 7. DOI:
10.1186/s40101-024-00354-7 - Cooper, J.; Tkatchenko, A. V. A Review of Current Concepts of the Etiology and Treatment of Myopia. Eye Contact Lens 2018, 44, 231–247. DOI:
10.1097/icl.0000000000000499 - Foster, P. J.; Jiang, Y. Epidemiology of Myopia. Eye 2014, 28, 202–208. DOI:
10.1038/eye.2013.280 - Haarman, A. E. G.; Enthoven, C. A.; Tideman, J. W. L. et al. The Complications of Myopia: A Review and Meta-analysis. Invest Ophthalmol Vis Sci. 2020, 61, 49. DOI:
10.1167/iovs.61.4.49 - Kaiti, R.; Shyangbo, R.; Sharma, I. P. Role of Atropine in the Control of Myopia Progression-A Review. Beyoglu Eye J. 2022, 7, 157–166. DOI:
10.14744/bej.2022.07742 - Tariq, F.; Mobeen, R.; Wang, X. et al. Advances in Myopia Prevention Strategies for School-aged Children: A Comprehensive Review. Front Public Health 2023, 11, 1226438. DOI:
10.3389/fpubh.2023.1226438
Related to this article