LC–MS Maps Blood Chemistry Changes in Viral Fevers

Author(s)John Chasse
Listen
0:00 / 0:00

Key Takeaways

  • LC–MS in two acquisition settings broadened chemical coverage and revealed group-wise clustering with partial overlap between infected and healthy cohorts, indicating both shared and infection-associated metabolic shifts.
  • Relative to controls, CHIKV, DENV, and IAV each showed hundreds of altered serum features in one mode and fewer in the other, with directionality varying by virus and setting.
SHOW MORE

Untargeted liquid chromatography–mass spectrometry (LC–MS) reveals serum changes in chikungunya virus, dengue virus, and the flu.

In their early stages, chikungunya virus (CHIKV), dengue virus (DENV), and influenza A virus (IAV) can look a lot alike, since all three usually start with a fever and similar symptoms. Standard lab tests give doctors helpful information, but they do not show the full picture of how each virus changes the body’s chemistry. That led a team of researchers to study the blood of patients with each infection. They used liquid chromatography–mass spectrometry (LC–MS) to scan for a wide range of small molecules, a broad approach called untargeted metabolomics, to see how each virus changes the chemical makeup of the blood. The team published the work in the journal Virus Research.¹

What Do Earlier Studies Show About How These Viruses Change Blood Chemistry, and What’s Missing?

Earlier research has shown that DENV, CHIKV, and IAV all change the body’s chemistry. In dengue, studies of blood have found that fats, protein-related chemicals, and chemicals tied to inflammation shift as the illness progresses.2,3 One team compared the blood of patients with CHIKV, DENV, or both at once, and found that each condition left its own chemical “fingerprint.”4 Another team tracked how blood chemistry changed over time in flu patients and compared those changes with dengue.5 Other studies have identified small molecules linked to whether someone has dengue and how sick they become.6

Together, this work showed that blood chemistry can help tell some viral infections apart. But none of these studies compared DENV, CHIKV, and IAV side by side with healthy people using the same method. Doing so, in the opinion of the researchers, could reveal both the changes the three infections have in common and the changes that are more typical of each one.1

How Did the Team Study the Patients’ Blood, and What Did They Find?

The researchers compared blood samples, taken at a single point in time, from patients with DENV, CHIKV, and IAV and from healthy people. They analyzed the samples with LC–MS, using two instrument settings that together pick up a wider range of molecules. They then processed the data to see how each infection changed the blood’s chemistry.1

To make sense of the results, the team ran a series of checks and statistical tests. They confirmed the data were reliable, looked for overall patterns that set the groups apart, and picked out the molecules that differed most between groups, with a correction to rule out chance findings. They sorted those molecules by the body processes they belong to, using a standard reference database (KEGG). Finally, they tested how well each molecule could tell the infections apart.1

The analysis picked up thousands of chemical signals in the blood, and the ones that could be identified were kept for comparison. Overall, each group’s blood chemistry tended to cluster together, although the healthy and infected groups overlapped somewhat. Compared with healthy people, each infection changed hundreds of chemical signals. Under the first instrument setting, the team found about 320 changed signals for CHIKV, 300 for DENV, and 295 for IAV. The second setting turned up fewer, roughly 30 to 50 per infection. Under the first setting, most of the changed chemicals were at lower levels than in healthy people. Under the second, whether levels went up or down depended on the virus.1

The changed chemicals were linked to several key body processes, including how the body handles fats, proteins (amino acids), and vitamins, and how it breaks down foreign substances such as drugs. Early tests suggested that several of the chemicals were very good at telling infected patients apart from healthy people. The researchers stress that this still needs to be confirmed in a separate group of patients. Further analysis looked more closely at which chemical changes the three infections shared, which way they moved, and which chemicals looked most promising as markers.1

“CHIKV, DENV, and IAV infections were associated with broad serum metabolic alterations compared with healthy controls,” wrote the authors of the paper.1 “The CHIKV-versus-control comparison yielded the largest number of altered metabolic features in the current dataset, although this observation should be interpreted cautiously because of unequal sampling proportions and the absence of direct comparisons between infection groups. Given the relatively small sample size, single-center and single-outbreak design, and lack of an independent validation cohort, the candidate metabolites identified in this study should be regarded as exploratory and require validation in larger independent cohorts and targeted metabolomic assays.”

Read More on Similar Topics
Anion-Exchange Chromatography and Biochemical Profiling of Covid-19 Vaccine Following Freeze–Thaw Cycles

References

  1. Ouyang, F.; Chen, X.; Wang, M. et al. Serum Untargeted Metabolomics Reveals Infection-associated Metabolic Alterations in Chikungunya, Dengue, and Influenza A Virus Infections. Virus Res. 2026, 199832. DOI: 10.1016/j.virusres.2026.199832
  2. Cui, L.; Lee, Y. H.; Kumar, Y, et al. Serum Metabolome and Lipidome Changes in Adult Patients with Primary Dengue Infection. PLoS Negl Trop Dis 2013,7 (8), e2373. DOI: 10.1371/journal.pntd.0002373
  3. Birungi, G.; Chen, S. M.; Loy, B. P. et al. Metabolomics Approach for Investigation of Effects of Dengue Virus Infection Using the EA.hy926 Cell Line. J Proteome Res. 2010, 9 (12), 6523-6534. DOI: 10.1021/pr100727m
  4. Shrinet, J.; Shastri, J. S.; Gaind, R. et al. Serum Metabolomics Analysis of Patients with Chikungunya and Dengue Mono/Co-infections Reveals Distinct Metabolite Signatures in the Three Disease Conditions. Sci Rep. 2016, 6, 36833. DOI: 10.1038/srep36833
  5. Cui, L.; Fang, J.; Ooi, E. E. et al. Serial Metabolome Changes in a Prospective Cohort of Subjects with Influenza Viral Infection and Comparison with Dengue Fever. J Proteome Res. 2017, 16 (7), 2614-2622. DOI: 10.1021/acs.jproteome.7b00173
  6. Voge, N. V.; Perera, R.; Mahapatra, S. et al. Metabolomics-Based Discovery of Small Molecule Biomarkers in Serum Associated with Dengue Virus Infections and Disease Outcomes. PLoS Negl Trop Dis. 2016, 10 (2), e0004449. DOI: 10.1371/journal.pntd.0004449