LCGC Advances In Gas Chromatography 11.23-11.24

Shun-Hsin Liang

Articles by Shun-Hsin Liang

A hybrid HILIC–ion exchange column was used for the analysis of ultrashort-chain per- and polyfluoroalkyl substances (PFAS) compounds in environmental waters. This direct injection LC–MS method enables simultaneous measurement of ultrashort- chain, alternative, and legacy PFAS in potable and non-potable waters.

Abuse of synthetic opioid prescription painkillers such as fentanyl, along with a rapidly growing list of illicit analogues, is a significant public health problem. In this study, we developed a simple dilute-and-shoot method that provides a fast 3.5-min analysis of fentanyl and related compounds (norfentanyl, acetyl fentanyl, alfentanil, butyryl fentanyl, carfentanil, remifentanil, and sufentanil) in human urine by liquid chromatography–tandem mass spectrometry (LC–MS/ MS) using a Raptor Biphenyl column.

Figure 1 L1563206491183.png

The Application Notebook

Abuse of synthetic opioid prescription painkillers such as fentanyl, along with a rapidly growing list of illicit analogues, is a significant public health problem. In this study, we developed a simple dilute-and‑shoot method that provides a fast 3.5-min analysis of fentanyl and related compounds in human urine by LC–MS/MS using a Raptor Biphenyl column.

Figure 11547472297205.png

The Application Notebook

Abuse of synthetic opioid prescription painkillers such as fentanyl, along with a rapidly growing list of illicit analogues, is a significant public health problem. In this study, we developed a simple dilute-and-shoot method that provides a fast 3.5-min analysis of fentanyl and related compounds (norfentanyl, acetyl fentanyl, alfentanil, butyryl fentanyl, carfentanil, remifentanil, and sufentanil) in human urine by LC–MS/MS using a Raptor Biphenyl column.

figure 1 L1537455853618.png

The Application Notebook

Abuse of synthetic opioid prescription painkillers such as fentanyl, along with a rapidly growing list of illicit analogues, is a significant public health problem. In this study, we developed a simple dilute-and-shoot method that provides a fast 3.5-min analysis of fentanyl and related compounds (norfentanyl, acetyl fentanyl, alfentanil, butyryl fentanyl, carfentanil, remifentanil, and sufentanil) in human urine by LC–MS/MS using a Raptor Biphenyl column.

figure 1 L1537522729157.png

LCGC Asia Pacific

The use of superficially porous particles (SPPs) for modern high performance liquid chromatography (HPLC) is now very common. Initially, SPPs rose as an alternative to sub-2-µm fully porous particles (FPPs). In recent years, many column manufacturers have developed 2-µm and smaller SPP-based products. This article investigates the practical utility of these smaller SPP designs.

figure 1 L1531748877283.png

LCGC Europe

The use of superficially porous particles (SPPs) for modern high performance liquid chromatography (HPLC) is now very common. Initially, SPPs rose as an alternative to sub-2-µm fully porous particles (FPPs). In recent years, many column manufacturers have developed 2-µm and smaller SPP-based products. This article investigates the practical utility of these smaller SPP designs.

figure 11541603006254.png

The Application Notebook

Abuse of synthetic opioid prescription painkillers such as fentanyl, along with a rapidly growing list of illicit analogues, is a significant public health problem. In this study, we developed a simple dilute-and-shoot method that provides a fast 3.5-min analysis of fentanyl and related compounds (norfentanyl, acetyl fentanyl, alfentanil, butyryl fentanyl, carfentanil, remifentanil, and sufentanil) in human urine by LC–MS/MS using a Raptor Biphenyl column.

Restek_logo_web-New-1437574354929.jpg

Special Issues

A rapid, accurate, and reproducible method was developed for high-throughput testing of nicotine, cotinine, trans-3’-hydroxycotinine, nornicotine, norcotinine, and anabasine in urine. Data show that a fast and highly efficient analysis of these basic compounds can be achieved with the Raptor Biphenyl column using standard reversed-phase LC–MS mobile phases that are compatible with a variety of LC–MS instrumentation.