Gas chromatography and comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC–TOFMS and GCxGC–TOFMS) were utilized to develop trace-level calibration curves in brewed green tea spiked with organochlorine and organophosphorus pesticide standards. A sensitive and robust calibration curve was developed from 10 to 500 parts per trillion (ppt), which allowed quantitative results to be determined for organochlorine–organophosphorus pesticides in brewed green tea. Exceptional limits of detection were achieved by GC–TOFMS and GCxGC–TOFMS at or below 10 ppt (solution concentration) for all but one of the pesticides. Stir bar sorption extraction (SBSE) was utilized to isolate the pesticide components from brewed green tea samples prior to analysis by GC–TOFMS and GCxGC–TOFMS. Different types of green tea were analyzed qualitatively by SBSE and GC–TOFMS with subsequent quantification for organochlorine–organophosphorus..

The Application Notebook

The Application Notebook

LCGC North America
Comprehensive GCxGC was employed for the separation of ICH and USP 1, 2, and 3 pharmaceutical solvents. The significantly improved peak capacity in GCxGC allows a single method for any combination of solvents and mitigates interference due to impurities in the solvents, diluents, analyte matrices, and from column or septum bleed, through the increased separation space.

Special Issues
The increased resolving power provided by comprehensive two-dimensional gas chromatography (GCxGC) extends the chromatographer's ability to rapidly detect and measure smaller components in complex mixtures beyond that which was possible previously, allowing for the identification of hazardous components in complex mixtures such as foodstuffs or emergency response samples. In target analysis, the increased numbers of peaks resulting from the sample matrix can be largely ignored during the review of data. However, when the nature of the analyte of interest is not entirely known, analysis of the samples might require screening through the entire peak table for compounds with specific chemical characteristics. For example, in the analysis of foodstuffs for pesticides (1,2), GCxGC coupled with a time-of-flight mass spectrometry (GCxGC–TOF-MS) can provide low detection limits for multiple analytes in these complex samples. Yet the question remains as to whether other toxic compounds, not included in the..

LCGC Asia Pacific
It may be somewhat audacious to claim that some methods in GCÃ-GC can be called non-classical - the technique has only been around for about 15 years and one might argue that this is not long enough to establish a suite of classical methods.

LCGC North America
October 2006. This brief review introduces the GCxGC technique and its advantages, hich primarily lie in the area of ncreased separation power for volatile chemical analysis.

The Application Notebook
Tincuta Veriotti, LECO Corporation

LCGC Europe
The latest newcomer to the collection of GC techniques, GCXGC, is examined in this instalment. Although this technique is capable of delivering more GC information in a shorter time than other methods, its technical complexity has slowed down widespread acceptance. John Hinshaw explains...

LCGC North America
John Hinshaw discusses advances in the field of two-dimensional gas chromatography.