Application Notes: Pharmaceuticals

i1-815569-1408536423739.jpg

The Application Notebook

Beverages, such as sodas and energy drinks, can include a number of polar ingredients, which are easily soluble in the water matrix of the drinks. These ingredients include sweeteners (sugars and sugar substitutes), caffeine, vitamin supplements, amino acids, organic acids, and plant extracts. Because the analytes are already in solution, there is no need for extensive sample preparation. Dilution followed by direct injection into an HPLC is typically suitable.

i1-815574-1408536414306.jpg

The Application Notebook

Caramel colorings are used as additives in a broad range of food and beverage products, but have no nutritional or preservative function. Recently, the potential hazard to humans of ammonia- and ammonia-sulfite-process caramel colorings was raised, because they contain the by-product 4-methylimidazole, which is a potential carcinogen (1).

i8_t-812288-1416911863495.jpg

Special Issues

A new type of method development that uses modeling to find the "best" separation for high performance liquid chromatography (HPLC) was investigated and principles of Quality by Design (QbD) were followed when planning the investigation. The process delivered precise results and the method was able be transferred to a routine quality control (QC) laboratory.

i3_t-805453-1408547113993.jpg

The Application Notebook

Phthalates are plasticizers that are added to plastics to make them softer and more flexible. Plastics that contain phthalates are commonly used in the manufacturing of toys. Since phthalates are not permanently bonded to plastics, they can be released from toys through touching, licking, and chewing.

i2-805465-1408547071098.gif

The Application Notebook

Sample pretreatment is often a time consuming and labor-intensive step which can be a restricting factor for the rapid analysis. This is especially true for the analysis of drugs in biofluids containing many interfering matrices.

i1-805463-1408547074811.jpg

The Application Notebook

EPA Method 8270 is used to determine the concentration of semi-volatile organic compounds in extracts prepared from solid waste matrices such as soils, air sampling media, and water samples. Extractions from water samples can be particularly difficult and time consuming due to the problematic analytes that need to be extracted, concentrated, and analyzed.

i1-805449-1417781419420.jpg

The Application Notebook

In this article, the analysis of bath salts (phenethylamine and cathionone compounds) from urine samples is demonstrated using polymeric solid phase extraction (SPE) sample preparation followed by HILIC chromatographic analysis with TOF-MS detection. HILIC chromatographic conditions on the Ascentis? Express HILIC phase are used for fast, high-resolution separation of nine synthetic bath salts.