Application Notes: GC

i2-479062-1408665270679.gif

PLOT columns are often used in GC analyses when it is necessary or desirable to retain one class of solutes in favour of other solutes that have little or limited interactions with the surface of the stationary phase. With a PLOT column, chromatographers can even cause lower boiling point compounds to elute well after higher boiling point compounds, thus providing better qualitative and quantitative separations for the solutes of interest.

i1-458029-1417781327406.jpg

The performance of lubricating oil is significantly degraded by the presence of fuel contaminants such as gasoline and diesel. Recycled oil is particularly susceptible to this form of contamination. Consequently, producers and distributors of lubricating oil must go to great lengths to ensure the levels of fuel contamination are kept to a safe limit (typically 4–5%) in these products.

i1-409919-1408660235408.jpg

The continual increase in sample numbers in busy labs means that it is often difficult for quality control or contract analysis labs to maintain short turnaround times, particularly when instruments are already running at full capacity. To address the need for faster analysis while retaining the quality of separation offered by dedicated amino acid analysers, an improved formulation of sodium citrate based buffers has been developed by Biochrom.

i4-397283-1408673017577.gif

Gas chromatography (GC) coupled to time-of-flight mass spectrometry (TOF-MS) offers unique solutions for various analytical applications including the analysis of food quality, authenticity and safety markers. This article provides a general overview of TOF-MS basic features, highlighting its advantages and limitations compared with GC using conventional mass analysers. Examples of recent results obtained for selected food contaminants and flavour components are described to illustrate the potential of this recently introduced technique.

i3-390802-1408681612263.gif

Soft drink formulas often include preservatives, artificial sweeteners, flavours or caffeine in their list of ingredients. Using the Acclaim OA column, as many as eight common additives may be determined in a single run. Many of these additives are hydrophilic organic acids for which this column was designed. Notably, benzoate and sorbate, which do not resolve on C18 columns at low pH, are fully separated.

i4-388997-1408683113497.jpg

Column lifetime is a more and more important issue when developing an analytical method for HPLC. Besides sample treatment, column cleaning and storage, operational parameters of the analytical method will have an influence on column lifetime. This question may not always be addressed early enough in the methods development process.

Protease inhibitors are a class of anti-HIV drugs used in combination therapy to block replication of the HIV virus in a person's blood. It is important to monitor the levels of these drugs in the patient since resistance can develop at low levels and at high levels the drug can exhibit toxic effects.

GC column bleed has been postulated to be caused by "backbiting" of the siloxane chain and volatility of noncrosslinked oligimers...