Application Notes: LC-MS

i4-388992-1408683125565.jpg

The Application Notebook

Accurate mass measurements are a key element of chemical characterization. However, the accepted mass accuracy tolerance of 3–5 ppm can still leave significant ambiguity in the proposed chemical formula. Consequently a further input from other analytical techniques such as NMR or MS/MS, along with some judgment based on the synthetic history is often required to arrive at a confident formula assignment.

i3-389398-1408682807836.gif

The Application Notebook

Glyphosate [N-(phosphonomethyl) glycine] is a broad spectrum, non-selective herbicide, which acts by inhibiting the shikimic acid pathway in plants. Recent studies have raised global health and environmental concerns about glyphosate's use.1 Glyphosate readily breaks down into aminomethyl phosphonic acid (AMPA) in the environment; requiring accurate measurement. Both highly polar compounds present an analytical challenge to the chromatographer (Figure 1). Typical silica based reversed-phase C18 columns experience difficulty with the retention of such polar compounds, and may generate non-resolved co-eluting peaks, often with polar analytes eluting in the void volume. Traditional analytical methods require complex eluents and time consuming derivatization steps to achieve retention on a reversed-phase support.

i4-388997-1408683113497.jpg

The Application Notebook

Column lifetime is a more and more important issue when developing an analytical method for HPLC. Besides sample treatment, column cleaning and storage, operational parameters of the analytical method will have an influence on column lifetime. This question may not always be addressed early enough in the methods development process.

The Application Notebook

(3R, 3’R)-zeaxanthin is one of several dietary carotenoids found in human ocular tissue. Research has shown that concentrations of zeaxanthin, as well as other carotenoids, are significantly lower than normal in the macula of persons diagnosed with neovascular age-related macular degeneration (AMD)...

The Application Notebook

Protease inhibitors are a class of anti-HIV drugs used in combination therapy to block replication of the HIV virus in a person's blood. It is important to monitor the levels of these drugs in the patient since resistance can develop at low levels and at high levels the drug can exhibit toxic effects.

Application Notes

The Application Notebook

Mini application notes summaries

Application Notes

The Application Notebook

Mini application note summaries...

The Application Notebook

As new directives and legislation intended to regulate both the herbal medicine and nutraceutical industry are imminent...

Application Notes

The Application Notebook

A selection of mini application note write-ups

The Application Notebook

GC column bleed has been postulated to be caused by "backbiting" of the siloxane chain and volatility of noncrosslinked oligimers...

The Application Notebook

The current concern over acrylamide levels in food has unexpectedly brought amino acid analysis to the forefront . . .

The Application Notebook

The analysis of highly polar analytes on traditional RP silica-based columns (without the use of ion-pair reagents etc) is difficult as . . .