Phenomenex, Inc.

Articles by Phenomenex, Inc.

Using oral fluid as the matrix, a viable and simple solid phase extraction method for a wide range of drugs is developed. Several oral fluid collection devices were evaluated to determine the effectiveness of the cleanup procedure, ultimately confirming that the method is both robust and widely applicable.

A suite of unknown drug compounds from whole blood are analyzed by LC–MS-MS, requiring the need for an effective yet nonspecific cleanup technique. The resulting method demonstrates a simple and fast sample preparation procedure that is suitable for screening many compounds.

A suite of unknown drug compounds from whole blood are analyzed by LC–MS-MS, requiring the need for an effective yet nonspecific cleanup technique. The resulting method demonstrates a simple and fast sample preparation procedure that is suitable for screening many compounds.

Fast analysis of 14 banned carcinogenic aromatic amines using a Kinetex EVO C18 core-shell HPLC/UHPLC column with narrow peak widths along with excellent resolution between all compounds of interest.

Fast analysis of 14 banned carcinogenic aromatic amines using a Kinetex EVO C18 core-shell HPLC/UHPLC column with narrow peak widths along with excellent resolution between all compounds of interest.

Better identification and quantitation of low level peptides utilizing the powerful combination of unique selectivity and core-shell performance gains found with Kinetex EVO C18 core-shell columns.

Better identification and quantitation of low level peptides utilizing the powerful combination of unique selectivity and core-shell performance gains found with Kinetex EVO C18 core-shell columns.

Rapid and comprehensive resolution of a cold medicine API screen that can easily be implemented on HPLC and UHPLC instrumentation using a high performance core-shell Kinetex 2.6 μm EVO C18 column

Rapid and comprehensive resolution of a cold medicine API screen that can easily be implemented on HPLC and UHPLC instrumentation using a high performance core-shell Kinetex 2.6 μm EVO C18 column

A high performance, pH stable core-shell Kinetex EVO C18 column obtains narrow peak shape and extremely useful resolution for a doxylamine formulation impurity profile.

A high performance, pH stable core-shell Kinetex EVO C18 column obtains narrow peak shape and extremely useful resolution for a doxylamine formulation impurity profile.

LCGC10_i1.gif

Cooking at high temperatures causes a chemical reaction between certain sugars and asparagine which causes acrylamide formation. In this technical note, we explore how to use Novum™ SLE tubes to clean up a coffee matrix in order to quantitate known acrylamide levels. The recovery is especially significant when you consider the polar nature of the acrylamide (LogP -0.27). In addition to high recoveries (>90 %), the low values for the standard deviation and %CV indicates method reproducibility.

Cooking at high temperatures causes a chemical reaction between certain sugars and asparagine which causes acrylamide formation. In this technical note, we explore how to use Novum™ SLE tubes to clean up a coffee matrix in order to quantitate known acrylamide levels. The recovery is especially significant when you consider the polar nature of the acrylamide (LogP -0.27). In addition to high recoveries (>90 %), the low values for the standard deviation and %CV indicates method reproducibility.