LCGC UST

Phenomenex, Inc.

Articles by Phenomenex, Inc.

LCGC North America

Using oral fluid as the matrix, a viable and simple solid phase extraction method for a wide range of drugs is developed. Several oral fluid collection devices were evaluated to determine the effectiveness of the cleanup procedure, ultimately confirming that the method is both robust and widely applicable.

LCGC North America

Improving and optimizing EPA Method 593 using solid phase extraction (SPE) enhances sensitivity and maximizes efficiency while screening by LC–MS-MS for different female birth control hormones present in drinking and waste water.

LCGC Europe

Using oral fluid as the matrix, a viable and simple solid phase extraction method for a wide range of drugs is developed. Several oral fluid collection devices were evaluated to determine the effectiveness of the cleanup procedure, ultimately confirming that the method is both robust and widely applicable.

LCGC North America

A suite of unknown drug compounds from whole blood are analyzed by LC–MS-MS, requiring the need for an effective yet nonspecific cleanup technique. The resulting method demonstrates a simple and fast sample preparation procedure that is suitable for screening many compounds.

LCGC Europe

A suite of unknown drug compounds from whole blood are analyzed by LC–MS-MS, requiring the need for an effective yet nonspecific cleanup technique. The resulting method demonstrates a simple and fast sample preparation procedure that is suitable for screening many compounds.

LCGC Europe

Fast analysis of 14 banned carcinogenic aromatic amines using a Kinetex EVO C18 core-shell HPLC/UHPLC column with narrow peak widths along with excellent resolution between all compounds of interest.

LCGC North America

Fast analysis of 14 banned carcinogenic aromatic amines using a Kinetex EVO C18 core-shell HPLC/UHPLC column with narrow peak widths along with excellent resolution between all compounds of interest.

LCGC Europe

Better identification and quantitation of low level peptides utilizing the powerful combination of unique selectivity and core-shell performance gains found with Kinetex EVO C18 core-shell columns.

LCGC North America

Better identification and quantitation of low level peptides utilizing the powerful combination of unique selectivity and core-shell performance gains found with Kinetex EVO C18 core-shell columns.

LCGC North America

Achieve excellent peak shape and resolution between the broad spectrum antibiotic cefaclor and its degredants using the unique selectivity and high efficiency of a Kinetex EVO C18 core-shell.

LCGC Europe

Rapid and comprehensive resolution of a cold medicine API screen that can easily be implemented on HPLC and UHPLC instrumentation using a high performance core-shell Kinetex 2.6 μm EVO C18 column

LCGC North America

Rapid and comprehensive resolution of a cold medicine API screen that can easily be implemented on HPLC and UHPLC instrumentation using a high performance core-shell Kinetex 2.6 μm EVO C18 column

LCGC Europe

A high performance, pH stable core-shell Kinetex EVO C18 column obtains narrow peak shape and extremely useful resolution for a doxylamine formulation impurity profile.

LCGC North America

A high performance, pH stable core-shell Kinetex EVO C18 column obtains narrow peak shape and extremely useful resolution for a doxylamine formulation impurity profile.

LCGC10_i1.gif

LCGC Europe

Cooking at high temperatures causes a chemical reaction between certain sugars and asparagine which causes acrylamide formation. In this technical note, we explore how to use Novum™ SLE tubes to clean up a coffee matrix in order to quantitate known acrylamide levels. The recovery is especially significant when you consider the polar nature of the acrylamide (LogP -0.27). In addition to high recoveries (>90 %), the low values for the standard deviation and %CV indicates method reproducibility.

LCGC North America

Cooking at high temperatures causes a chemical reaction between certain sugars and asparagine which causes acrylamide formation. In this technical note, we explore how to use Novum™ SLE tubes to clean up a coffee matrix in order to quantitate known acrylamide levels. The recovery is especially significant when you consider the polar nature of the acrylamide (LogP -0.27). In addition to high recoveries (>90 %), the low values for the standard deviation and %CV indicates method reproducibility.