Podcasts

Join Hunsoo Park, Team Leader of Catalytic Process Development at SK pharmteco, as he discusses how integrating catalyst design, process development, and fixed-bed flow technology can improve pharmaceutical manufacturing from early development through commercialization. Through real-world case studies, Hunsoo explores when catalyst optimization can create value beyond off-the-shelf solutions, how to evaluate batch versus continuous flow processing, and strategies for improving selectivity, process robustness, scalability, and cost. Whether you're optimizing an existing catalytic step or developing a new process, this podcast offers valuable perspectives on building more efficient and commercially successful manufacturing processes.

Welcome to “Analytically Speaking,” the podcast from LCGC International and Spectroscopy. Here in Episode #49, podcast host Dr. Jerry Workman speaks with Dr. Mustafa Kansiz, who is currently the Director of Product Management at Photothermal Spectroscopy Corporation in Santa Barbara, California. Picking up where Episode #43 left off, they follow optical photothermal infrared (O-PTIR) spectroscopy from how it works to what it reveals, asking three deceptively simple questions about the world’s smallest particles: What is it? Where is it? And what is happening around it? This is Part 1 of a two-part conversation. Across both parts, the conversation travels from microplastics inside intestinal cells and human colon tissue, to nanoplastics and protein misfolding, bioaerosols that defeat Raman because of fluorescence, the chemistry of inhaled medicines, single bacterial cells facing antibiotics, contamination in hard-drive manufacturing, ancient microfossils, and corroding sixteenth-century glass and brass. Along the way, they discuss why precisely locating a particle is part of the measurement, and how to keep the claims tied to what the experiments actually show.

Welcome to “Analytically Speaking,” the podcast from LCGC International and Spectroscopy. In this episode, podcast co-hosts Dr. Dwight Stoll and Dr. James Grinias talk with Dr. Mark Schure, who has worked in separation science for over 35 years in both industry and academia. Over a 28-year period, he worked for Digital Equipment Corporation, the Rohm and Haas Company, and the Dow Chemical Company. Since then, he has served as Chief Technology Officer for Kroungold Analytical, and he has been an adjunct professor in the Department of Chemical and Biomolecular Engineering at the University of Delaware for over 20 years. Dr. Schure is a widely recognized expert in separation science who has published more than 110 papers, holds numerous patents, and edited the book Multidimensional Liquid Chromatography. His scientific interests encompass the fundamental separation science of complex molecules, polymers, and colloids, alongside 2D chromatography, retention mechanisms, and field flow fractionation. He has received numerous accolades, including the Eastern Analytical Symposium Award in Separation Science and the Uwe Neue Award from the HPLC conference. In a wide ranging conversation recorded live at the HPLC 2026 conference in Indianapolis following a memorial session for Prof. Peter Carr, we explore Mark’s unique entry into separation science, which benefited from prior experiences building amplifiers and electronics before transitioning to write Fortran software as a consultant for chemists at Northeastern University. We then discuss Mark’s foundational simulation work in field flow fractionation (FFF), including his approaches to modeling Coriolis effects and sedimentation. We also spend some time talking about Mark’s pioneering theoretical contributions to 2D chromatography on topics including sampling rate and detection limits. Finally, Mark shares his perspective on the intense inter-diffusion of information between his modeling group and Pete Carr and Ilja Siepmann at the University of Minnesota, the future of analytical chemistry, the need for improved analytical strategies for complex matrices like exosomes, and the potential for artificial intelligence to help identify unknown compounds in complex mixtures.

Welcome to “Analytically Speaking,” the podcast from LCGC International and Spectroscopy. Here in Episode #47, podcast host Dr. Jerry Workman speaks with Dr. Thomas Mayerhöfer from the Leibniz Institute of Photonic Technology (Leibniz IPHT) in Jena, Germany, and Friedrich Schiller University Jena, about “the other half” of the Beer–Lambert law: dispersion theory, the concentration law of the refractive index, and refractive-index and complex-valued chemometrics. Dr. Mayerhöfer, who first joined the podcast for Episode #29 on the history and theory of infrared spectroscopy, returns to explain how Beer’s law falls out of dispersion theory as a limiting case, why the refractive index obeys a concentration law of its own that was mainstream physical chemistry before about 1920 (and helped confirm the Kekulé structure of benzene), and how new refractive-index and complex-valued chemometric methods — in combination with PLS — can outperform conventional absorbance-based calibration by up to an order of magnitude.

In this episode, podcast co-hosts Dr. Dwight Stoll and Dr. James Grinias talk with two recent award winners live from the Pittcon conference in San Antonio, Texas: Dr. Bob Pirok and Dr. Justin Godinho. Dr. Bob Pirok is an Associate Professor at the University of Amsterdam in the Netherlands, where he also completed his Ph.D. under the direction of Professor Peter Schoenmakers. He is an expert in multi-dimensional chromatography and the application of machine learning within the field. At Pittcon we celebrated his receipt of the Emerging Leader in Chromatography Award, presented by LCGC International Magazine. Dr. Justin Godinho is a Senior Principal Scientist at GlaxoSmithKline (GSK) in Upper Providence, Pennsylvania. He completed his undergraduate work at Davidson College and his Ph.D. under the direction of Professor Jim Jorgenson at the University of North Carolina at Chapel Hill. Before joining GSK, he worked in the column manufacturing business with Advanced Materials Technology. He is a recognized expert in column technology at both capillary and analytical scales, as well as the analysis of small and biotherapeutic molecules. At this year's conference, he received the Young Investigator in Separation Science Award, sponsored by the ACS Division of Analytical Chemistry. In the conversation, we discuss the recent award sessions for both guests and the evolution of their respective careers. We explore Justin’s transition from fundamental column packing research to biopharmaceutical applications at GSK, touching on the ongoing need for protein-suitable columns, capillary-scale techniques, and the Hydrophobic Subtraction Model column database. We then shift to Bob’s research on automated method development discussed at the meeting. This includes a deep dive into data-driven chromatography, the complexities involved in establishing effective Chromatographic Response Functions (CRFs), and why setting realistic expectations for artificial intelligence and automated method development is critical to avoiding a future "AI winter."

The October 2025 FDA draft guidance for biosimilars marks a major shift toward greater reliance on analytical data. Most notably, it signals a move to reduce or even eliminate comparative efficacy studies when robust analytics can provide equivalent insight, detecting subtle differences that clinical studies often miss. Biosimilar development will continue to require comprehensive analytical packages, with emphasis on orthogonal techniques. This session features Colette Quinn from Waters Corporation, who discusses how analytics support biosimilar development and help meet the FDA’s “totality-of-evidence” expectations.

In this podcast, Lorna De Leoz, Agilent Global Food Segment Director, highlights all things PFAS in food and beverage testing. From the emerging safety concerns from PFAS and how it has a major impact on our food supply to the importance of testing PFAS in food and inherent challenges. With global legislation rapidly changing, manufacturers face challenges on how to test and meet the requirements to maintain safe food. Listen now to learn about the current challenges and what the future landscape of PFAS in food, ingredient, and beverage testing may look like.

On the latest Analytically Speaking podcast, Dwight Stoll and James Grinias chat with Kelly Hines from the University of Georgia in Athens, USA, about her journey into analytical chemistry—and her work using IMS-MS and chromatography for multi-omics studies at the metabolite level.

Leslie Wubbel, SaaS Product Manager at LabVantage, shares how the LabVantage cloud-based Laboratory Information Management System (LIMS) platform enables laboratories to digitally transform operations, unify workflows, and improve scalability across various industries. The discussion highlights market forces driving LIMS adoption, projected to grow by $1.6 billion, and explains how the platform utilizes Software as a Service (SaaS) and AI capabilities to accelerate R&D and go-to-market timelines. Learn more about:

In this episode of Analytically Speaking, explore the intersection of forensic science and cannabis research with Brent Wilson as he shares insights on analytical chemistry and standards.

In this podcast, Daniel DeBord, CTO of MOBILion Systems, describes a new high resolution mass spectrometry approach that promises to increase speed and sensitivity in omics applications. MOBILion recently introduced the PAMAF mode of operation, which stands for parallel accumulation with mobility aligned fragmentation. It substantially increases the fraction of ions used for mass spectrometry analysis by replacing the functionality of the quadrupole with high resolution ion mobility. Listen to learn more about this exciting new development.

Peter Pellegrinelli, Applications Specialist at Advanced Materials Technology (AMT) explains the complexity of oligonucleotide separations due to the unique chemical properties of these molecules. Issues such as varying length, sequence complexity, and hydrophilic-hydrophobic characteristics make efficient separations difficult. Separation scientists are addressing these challenges by modifying mobile phase compositions, using varying ion-pairing reagents, and exploring alternative separation modes like HILIC and ion-exchange chromatography. Due to these complexities, AMT has introduced the HALO® OLIGO column, which offers high-resolution, fast separations through its innovative Fused-Core® technology and high pH stability. Alongside explaining the new column, Peter looks to the future of these separations and what is next to come.

Deriving antibodies from plasma products involves several steps, typically starting from the collection of plasma and ending with the purification of the desired antibodies. These are: plasma collection; plasma pooling; fractionation; antibody purification; concentration and formulation; quality control; and packaging and storage. This process results in a purified antibody product that can be used for therapeutic purposes, diagnostic tests, or research. Each step is critical to ensure the safety, efficacy, and quality of the final product. Applications of AI/GenAI in many of these steps can significantly help in the optimization of purification and yield of the desired antibodies. Some specific use-cases are: selecting and optimizing plasma units for optimized plasma pooling; GenAI solution for enterprise search on internal knowledge portal; analysing and optimizing production batch profitability, inventory, yields; monitoring production batch key performance indicators for outlier identification; monitoring production equipment to predict maintenance events; and reducing quality control laboratory testing turnaround time.