Application Notes: General

Sponsored Content

This comprehensive peer-reviewed set of more than 600 definitions covers topics of interest for the biopharmaceutical and gene therapy subjects of genetics, therapeutics, drug development, clinical medicine, and the analytical science tools used for characterization of drugs. This glossary serves as a helpful reference to both novice and advanced scientists, engineers, and business executives involved with biopharmaceuticals and gene therapy technologies. Online sources of information for topics covered in this guide are also included for additional insights.

Sponsored Content

This study demonstrates high-throughput analysis of BTEX compounds from several matrices (air, water and soil). Detection limits in the single-digit part-per-billion concentration range (by volume) are readily achievable within seconds using SIFT-MS, because sample analysis is achieved without chromatography, pre-concentration, or drying. We also present a calibration approach that enables speciation of ethylbenzene from the xylenes in real time.

Sponsored Content

This publication reviews VOC pollutant monitoring applications of SIFT-MS in South Korea. SIFT-MS has been applied to emission source characterization, fenceline monitoring, ambient monitoring, pollution mapping, and incident response (including the use of drone-based sampling) for hazardous air pollutants (HAPs), odor nuisance species, and compounds that have high ozone formation potential (OFP) and/or contribute to secondary aerosol (SOA) formation.

Sponsored Content

Agilent workflow solutions, designed for the food and beverages industry, serve as a comprehensive resource for testing alternative proteins. This compendium provides 15 applications across various domains, such as taste and flavor, nutrition, food quality, and food safety leveraging advanced analytical techniques like ICP-MS, LC/MS, GC/MS, and HPLC.

Sponsored Content

This application note demonstrates that automated headspace-SIFT-MS analysis has the potential to screen larger sample numbers for the volatile MOH fraction, providing a rapid indication of packaging material contamination. As benzene has also recently been found to be problematic in commercial products, Headspace-SIFT-MS can screen over 220 samples per day for volatile MOSH and MOAH compounds – nearly seven-fold more samples than the routine liquid and gas chromatography method.

Sponsored Content

This innovative AEX method replaces toxic TMAC with non-toxic choline-Cl, ensuring safety and efficiency in AAV capsid analysis, applicable across multiple AAV serotypes.

Sponsored Content

The use of method development software with analytical quality by design (AQbD) approaches can produce robust methods but are limited by both access to the software and user proficiency. Other approaches require more manual intervention to select the correct conditions, interpret the results, and make decisions based on the data. This application note, we explore using a systematic screening protocol to develop a method for the analysis of a mixture of nine structurally similar spice cannabinoids.

Sponsored Content

Advances in LC-MS/MS technology have allowed for a more comprehensive and rapid multi-class drug method to be developed. This highlighted method allows for the use of a protein precipitation and sample filtration with Thomson eXtreme|Filter Vials® followed by a rapid 8 min/sample run time, thus allowing for the reduction in multiple LC-MS/MS methods being run in the laboratory, freeing up valuable instrument time.

Sponsored Content

Triazine herbicides are commonly used in crop management to remove invasive plant species. These herbicides disrupt the photosynthesis cycle, leading to plant death and can contaminate soil and groundwater if used in high enough concentrations and for long enough duration. As such, the monitoring of these herbicides is important to minimize and monitor contamination. The app note outlines using a systematic screening protocol to develop a method for the analysis of a mixture of seven structurally similar triazine herbicides.

Sponsored Content

Often, method development activities are performed “on the fly” with tight timelines to achieve the goal of developing robust methods quickly. Unfortunately, the approach to method development is an often-overlooked aspect of the process. In this app note, we talk about employing a systematic screening protocol, which utilizes a structured decision-making process, alleviates the pressure on the analyst to select the best set of conditions, and streamlines the method development process.

Sponsored Content

Quantitative ethylene oxide analysis in Polysorbate 80 excipient is greatly simplified using SIFT-MS, with a time to first test result that is eight-fold faster than the current compendial method and a daily sample throughput that is 9- to 14-fold higher. In this application note, a simplified EtO method is presented that uses a much smaller quantity of PS80 for analysis than headspace GC-FID.

Sponsored Content

This application note describes head-to-head comparison of GC-FID and SIFT-MS analyses of Class 2A and 2B residual solvents. The techniques perform similarly for linearity and repeatability, but SIFT-MS provides superior performance for accuracy and recovery. Furthermore, SIFT-MS provides greater than 11-fold increase in sample throughput and significantly reduces the time taken to report quantitative results (over six times faster for a full calibration set).